19 Years Professional Heat Pump Manufacturer!
Place of Origin: | Guangzhou China |
Brand Name: | Meeting |
Certification: | CE ISO CCC UKAS,ROHS |
Model Number: | MDS50D |
Minimum Order Quantity: | 5 PCS |
---|---|
Price: | Negotiation |
Packaging Details: | Plywooden case |
Delivery Time: | 15 days |
Payment Terms: | T/T, L/C WESTERN UNION |
Supply Ability: | 800/MONTH |
Materail: | Galvanized Steel Sheet | Contactor: | Fuji Brand |
---|---|---|---|
Copper Pipe Thick: | 1 Mm | Compressor: | ZW Series ,With Crank Heating |
Working Temperature: | -20--45 Degree | Insulation: | Foam Pack Pipe And Stick On The Machine Innner |
Defrosting: | Automaticlly | Temperature: | 80 Degree |
High Light: | hybrid heat pump,geothermal water to water heat pump |
5P meeting_MDS50D water source heat pump_380V Copeland compressor hot water heating house save power high temprature
Technology Specification
Water source heat pump
MODEL | Unit | MDS15D | |
Rated heating capacity | KW | 5 | |
Hot water supply | L/h | 100 | |
Average heating input power | KW | 1.2 | |
Rated heating input current | A | 6 | |
Max outlet water temp | ℃ | 80 | |
COP | 4 | ||
Power | V/Hz | 220V/50 | |
Noise | Db(a) | 50 | |
Dimension | W*D*H | mm | 657×557×765 |
Packing size | W*D*H | mm | 737×637×915 |
Unit weight | KG | 75 | |
Refrigerant | R134A | ||
Working air temp range | ℃ | (-40℃)—45℃ | |
compressor | Type | Panasonic | |
water source heat exchanger | Type | Plate heat exchange | |
Pipe size | DN | 25 | |
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 2000L/h | |
Water pressure down | Kpa | 30 | |
Pipe size | DN | 25 | |
Max house heating | M2 | 40 | |
MODEL | Unit | MDS20D | |
Rated heating capacity | KW | 7 | |
Hot water supply | L/h | 150 | |
Average heating input power | KW | 1.7 | |
Rated heating input current | A | 9 | |
Max outlet water temp | ℃ | 80 | |
COP | 4 | ||
Power | V/Hz | 220V/50 | |
Noise | Db(a) | 50 | |
Dimension | W*D*H | mm | 657×557×765 |
Packing size | W*D*H | mm | 737×637×915 |
Unit weight | KG | 75 | |
Refrigerant | R134A | ||
Working air temp range | ℃ | (-40℃)—45℃ | |
compressor | Type | Panasonic | |
water source heat exchanger | Type | Plate heat exchange | |
Pipe size | DN | 25 | |
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 2000L/h | |
Water pressure down | Kpa | 30 | |
Pipe size | DN | 25 | |
Max house heating | M2 | 55 | |
MODEL | Unit | MDS30D | |
Rated heating capacity | KW | 12 | |
Hot water supply | L/h | 260 | |
Average heating input power | KW | 2.89 | |
Rated heating input current | A | 13/6 | |
Max outlet water temp | ℃ | 80 | |
COP | 4 | ||
Power | V/Hz | 220V/380V/50 | |
Noise | Db(a) | 50 | |
Dimension | W*D*H | mm | 657×557×765 |
Packing size | W*D*H | mm | 737×637×915 |
Unit weight | KG | 108 | |
Refrigerant | R134A | ||
Working air temp range | ℃ | (-40℃)—45℃ | |
compressor | Type | Copeland | |
water source heat exchanger | Type | Plate heat exchange | |
Pipe size | DN | 25 | |
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 3300L/h | |
Water pressure down | Kpa | 35 | |
Pipe size | DN | 25 | |
Max house heating | M2 | 100 | |
MODEL | Unit | MDS40D | |
Rated heating capacity | KW | 16 | |
Hot water supply | L/h | 380 | |
Average heating input power | KW | 4 | |
Rated heating input current | A | 9 | |
Max outlet water temp | ℃ | 80 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 50 | |
Dimension | W*D*H | mm | 657×557×765 |
Packing size | W*D*H | mm | 737×637×915 |
Unit weight | KG | 145 | |
Refrigerant | R134A | ||
Working air temp range | ℃ | (-40℃)—45℃ | |
compressor | Type | Copeland | |
water source heat exchanger | Type | Plate heat exchange | |
Pipe size | DN | 32 | |
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 4000L/h | |
Water pressure down | Kpa | 40 | |
Pipe size | DN | 25 | |
Max house heating | M2 | 125 | |
MODEL | Unit | MDS50D | |
Rated heating capacity | KW | 19 | |
Hot water supply | L/h | 400 | |
Average heating input power | KW | 4.4 | |
Rated heating input current | A | 9 | |
Max outlet water temp | ℃ | 80 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 50 | |
Dimension | W*D*H | mm | 657×557×765 |
Packing size | W*D*H | mm | 737×637×915 |
Unit weight | KG | 145 | |
Refrigerant | R134A | ||
Working air temp range | ℃ | (-40℃)—45℃ | |
compressor | Type | Copeland | |
water source heat exchanger | Type | Plate heat exchange | |
Pipe size | DN | 32 | |
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 5000L/h | |
Water pressure down | Kpa | 40 | |
Pipe size | DN | 25 | |
Max house heating | M2 | 150 | |
MODEL | Unit | MDS60D | |
Rated heating capacity | KW | 25 | |
Hot water supply | L/h | 520 | |
Average heating input power | KW | 6 | |
Rated heating input current | A | 12 | |
Max outlet water temp | ℃ | 80 | |
COP | 4.5 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 50 | |
Dimension | W*D*H | mm | 657×557×765 |
Packing size | W*D*H | mm | 737×637×915 |
Unit weight | KG | 158 | |
Refrigerant | R134A | ||
Working air temp range | ℃ | (-40℃)—45℃ | |
compressor | Type | Copeland | |
water source heat exchanger | Type | Plate heat exchange | |
Pipe size | DN | 32 | |
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 6000L/h | |
Water pressure down | Kpa | 45 | |
Pipe size | DN | 25 | |
Max house heating | M2 | 175 | |
Model | Unit | MDS100D | |
Rated heating capacity | KW | 38 | |
Hot water supply | L/h | 800 | |
Average heating input power | KW | 8.8 | |
Rated heating input current | A | 18 | |
Max outlet water temp | ℃ | 80 | |
COP | 4.6 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 55 | |
Dimension | W*D*H | mm | 1050*810*760 |
Packing size | W*D*H | mm | 1140*900*910 |
Unit weight | KG | 290 | |
Refrigerant | R134A | ||
Working air temp range | ℃ | (-40℃)—45℃ | |
compressor | Type | Copeland | |
water source heat exchanger | Type | Plate heat exchange | |
Pipe size | DN | 32 | |
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 10000L/h | |
Water pressure down | Kpa | 50 | |
Pipe size | DN | 32 | |
Max house heating | M2 | 300 | |
Model | Unit | MDS150D | |
Rated heating capacity | KW | 42 | |
Hot water supply | L/h | 1200 | |
Average heating input power | KW | 11 | |
Rated heating input current | A | 21 | |
Max outlet water temp | ℃ | 80 | |
COP | 4.6 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 55 | |
Dimension | W*D*H | mm | 1050*810*760 |
Packing size | W*D*H | mm | 1140*900*910 |
Unit weight | KG | 300 | |
Refrigerant | R134A | ||
Working air temp range | ℃ | (-40℃)—45℃ | |
compressor | Type | Copeland | |
water source heat exchanger | Type | Plate heat exchange | |
Pipe size | DN | 32 | |
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 15000L/h | |
Water pressure down | Kpa | 50 | |
Pipe size | DN | 32 | |
Max house heating | M2 | 350 | |
MODEL | Unit | MDS200D | |
Rated heating capacity | KW | 74 | |
Hot water supply | L/h | 1590 | |
Average heating input power | KW | 17.6 | |
Rated heating input current | A | 36 | |
Max outlet water temp | ℃ | 80 | |
COP | 4.6 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 58 | |
Dimension | W*D*H | mm | 1260×850×860 |
Packing size | W*D*H | mm | 1350×910×1020 |
Unit weight | KG | 630 | |
Refrigerant | R134A | ||
Working air temp range | ℃ | (-40℃)—45℃ | |
compressor | Type | Copeland | |
water source heat exchanger | Type | Plate heat exchange | |
Pipe size | DN | 63 | |
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | M3/H | 20000L/h | |
Water pressure down | Kpa | 55 | |
Pipe size | DN | 50 | |
Max house heating | M2 | 600 | |
MODEL | Unit | MDS300D | |
Rated heating capacity | KW | 100 | |
Hot water supply | L/h | 2400 | |
Average heating input power | KW | 25 | |
Rated heating input current | A | 45 | |
Max outlet water temp | ℃ | 80 | |
COP | 4.6 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 55 | |
Dimension | W*D*H | mm | 1260×850×860 |
Packing size | W*D*H | mm | 1350×910×1020 |
Unit weight | KG | 660 | |
Refrigerant | R134A | ||
Working air temp range | ℃ | (-40℃)—45℃ | |
compressor | Type | Copeland | |
water source heat exchanger | Type | Tube heat exchange | |
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | M3/H | 30000L/h | |
Water pressure down | Kpa | 60 | |
Pipe size | DN | 50 | |
Max house heating | M2 | 730 |
Product Description
Applicable scope: The reservoir farms near the rivers and lakes, hotels, schools, hospitals, factory staff quarters and other places.
1. Water source heat pump system is a highly efficient and energy efficient refrigeration system that utilizes underground shallow geothermal resources (also known as ground energy, including groundwater, soil, or surface water). Stable geothermal resources throughout the year to meet the hot and cold demand, it is the best choice for alpine region to get hot water and heating.
2.The machine adopts international brand-name compressor, with patented technology efficient heat exchanger, refrigeration and heating more powerful, high efficiency, automatic micro computer intelligent control technology, set the multiple protection function.
Our Services
2. Intelligent Controlling service system will be avoid the long distance of the after sale problem. Wherever are you, our engineer can be controlled your equipment, when some questions occur on the equipment. Just tell us what number will be shown on the screen, then the engineer will be solve the problem.
3. We accept OEM, ODM and customization.
4.24*7 after sales service. You will get satisfied service.
5. We have More than 17years production and sales experience; Professional sales team.
6. Fast delivery time: small order: 3-5 days, bulk order: 15-25 days.
Water to water system pumps heat through the use of a simple refrigeration system, it pumps heat from the warm earth in the winter and move it into your house or business. In the summer, the process is reversed. Since it costs far less to move heat than to make it, much less energy is consumed.
For closed loop system, water or an antifreeze solution is circulated through plastic pipes buried beneath the earth’s surface. During the winter the fluid collects heat from the earth and carries it through the system and placing it in the ground.
Open systems operate on the same principle as closed loop systems and can be installed where an adequate supply of suitable water is available and open discharges is feasible.
Loops can be installed three ways: horizontally, vertically or in a pond or lake. The type chosen depends on the available land area and the soil and rock type at the installation site.
Monoblock evi air to water source heat pump factory description:
* Products design and produce heat pump by European standard EN14511, approved by ECM with its high efficiency. Factory audited by Bureau Veritas.
* Delivers higher capacity at low evaporating temperature thereby better responding to heating requirement thanks to EVI compressor
* It also results in less supplementary heating to cover the full heating demand on the coldest days.
* Workable ambient temperature range - 25℃ to 35℃.
* Two speed energy saving fan motors. The speed of fan varies so only the required amount of air is utilized. The blades are specially designed to move as much air as possible at the lowest noise level.
* Timer ON/OFF.
* Varied heat curve. Controlled water temperature varies according to ambient temperature
* Most components are well sealed to retain heat and prevent dripping
1. Copeland EVI scroll R407C compressor.
2. Designed for central heating for houses in cold area including North Europe and East Europe.
3. Can work stably at -25DegC ambient and the COP at -15DegC ambient is up to 2.5.
4. Can work with auxiliary heater.
5. Using electronic expansion valve, achieving accurate, stable and high efficiency throttling.
6. Split design, no water system outside, no freezing and damage to water system. Optional refrigerant pipe quick connection is available, to reduce installation cost.
7. Low noise design for the outdoor unit. The compressor is on a floating plate to reduce vibration at the most extent. Noise insulation inside the cabinet. The fan is extremely quiet.
8. The refrigerant connections are designed to allow hiding all pipes, wires into the ground to ensure good looking installation.
ABOUT US
1). We were established in 2001.
2).We are a professional heat pump manufacturer, Located around Baiyun Air port
3). We are trading on Meeting Brand ,Meeting heat pump Well-know brand we operate in Europe market
4). Our company has been inspected and certificated by TUV and SGS.
5).We are the one of the first manufacturers whose heat pumps are with top COP gaining grants from Chinese government.
6).We passed ISO 9001 quality management system and ISO14000 environment protection system
7). Our testing laboratory can test heat pump up to 60KW heating capacity and create testing air temperature condition during -25DegC~45DegC,according to EN14511 standard.
9). Our leading products: Air to water heat pump , DC inverter heat pump, High water temperature heat pumps,
Mono block house heating heat pumps, Split heat pump, super low noise heat pump
Heat pump dryer, Ground source heat pump, water to water heat pump, swimming pool heat pump
Contact Person: Ms. Alinna
Tel: +86 13922152741
Fax: 86-20
Save 75% Power Water To Air Heat Pump , Commercial Electric Air To Water Heat Pump
Meeting Electric Heat Pump System , 16 Kw Low Temperature Air Source Heat Pump
Household Electric Air Source Heat Pump Lower Heat Dissipate Long Operating Life
Electric Most Efficient Air Source Heat Pump , Ductless Heating And Cooling Units
Meeting water source heat pump water to water heat pumps can work good at extremly cold climate
Industrial Cold Climate Water Cooled Heat Pump , Geothermal Water To Water Heat Pump
High Cop Ground Source Heat Pump , High Water Temperature Geothermal Heat Pump
High Standard Water Source Heat Pump Wall Mounted EVI DC Inverter High Efficient
Swimming pool heat pump for water heating system.meeting 6P antiseptic chiller
Multifunction Swimming Pool Heat Pump Heating Capacity 380V / 220v 19kw 1120 * 490 * 1270mm
Most Efficient Pool Heat Pump , 380V 50kw Water Source Heat Pump Freestanding
Cold Water To Water Heat Pump Freestanding , Swimming Pool Air Source Heat Pump