Home ProductsGround Source Heat Pump

Integrated Cooling And Heating System Geothermal Source Heat Pump MDS20D

Integrated Cooling And Heating System Geothermal Source Heat Pump MDS20D

  • Integrated Cooling And Heating System Geothermal Source Heat Pump MDS20D
  • Integrated Cooling And Heating System Geothermal Source Heat Pump MDS20D
  • Integrated Cooling And Heating System Geothermal Source Heat Pump MDS20D
Integrated Cooling And Heating System Geothermal Source Heat Pump MDS20D
Product Details:
Place of Origin: Guangzhou China
Brand Name: Meeting
Certification: CB,CE,CSA,EMF,GS,LFGB,RoHS
Model Number: MDS20D-DY
Payment & Shipping Terms:
Minimum Order Quantity: 5 PCS
Price: Negotiation
Packaging Details: Plywooden case
Delivery Time: 15 days
Payment Terms: T/T, WESTERN UNION
Supply Ability: 800/MONTH
Contact Now
Detailed Product Description
Materail: Coated Matel Contactor: Fuji Brand
Copper Thick: 0.8--1 Mm Compressor: Famous Brand With Oil Heater
Display: LCD Finger Touch Control: Wifi Function Support
High Light:

ground loop heat pump

,

underground heat pump

Meeting Integrated cooling and heating system geothermal source heat pump MDS20D

 

Contact: Karmen | Heat Pump Professional Provider
Mobile/Wechat: +86 13902403715
Email:meeting13@heatpumpchina.com

 

Technology Specification
 
Quick Details:


 

Input power: 1.8KW Noise Db: ≤ 40Db
Heating capacity: 7.5KW Load side water flow:3000L/H
Cooling capacity: 5.4KW Heat source side water flow: 2000L/H
Rated voltage: 220V/50HZ Hot water side water pipe interface: DN25
Rated current: 8A Water source side water pipe interface: DN32
Water production: 160L/H Throttle element: thermal valve
Rated water temperature: 55 ° C Evaporator: shell and tube heat exchanger
Maximum water temperature: 60 ° C Condenser: casing heat exchanger
Cold water temperature drop: 3-5 ° C Air conditioning end: plate heat exchanger
Remarks: Initial/final water temperature of load side :15℃/55℃,Initial/outlet water temperature of source side, 15℃/ 10℃

 

 

Porduct feature:

 

1. Apply for imported compressor and famous accessories, reasonable match makes unit performance perfect.

 

2. Apply unique dimensional structure design, smaller installation size and no affect for indoor decoration appearance.

 

3. Unit can be used independently or in modular mode, each unit can be independent charged for easy check computation.

 

4. Apply for advanced microcomputer control for easy understanding for unit status.

 

5. High-efficient sound absorption &heating insulating material and double layered vibration damped on design, it features low-noise and bring enjoyment for security.

 

6. Each maintain, only to demount maintenance plate to repair, it features modular design, other units still can normally operate during maintenance.

 

 

Installation different situations:

 

The ground source heat pump can also be called a soil source. It is buried in underground soil with high-polyethylene U-shaped pipe filled with water and antifreeze. The two ends of the pipe are connected to the evaporator in the ground source heat pump. Water and antifreeze are The circulation in the pipelines will continuously transfer the heat in the soil to domestic water.

 

 

 

Ground source heat pump principle

 

The difference between the water source heat pump and the air source is that the low-temperature and low-pressure liquid refrigerant exchanges heat with the water in the water/ground source pipeline in the evaporator, absorbs the heat Q1 in the water and evaporates into a low-temperature and low-pressure gaseous state, and then enters into a vaporized state. Compressor works through compressor W, is compressed into high temperature and high pressure gas, then enters condenser, exchanges heat with indoor water, transfers heat Q2 to indoor water, and the refrigerant condenses into high temperature and high pressure liquid, and then enters the expansion valve. With throttling, the refrigerant becomes a low-temperature and low-pressure liquid, and the throttling refrigerant enters the evaporator and undergoes heat exchange and evaporation, thereby realizing inverse carnot
The whole process, also Q2=Q1+W in this process

 

Integrated Cooling And Heating System Geothermal Source Heat Pump MDS20D 0

 

A. Payment service

 

1. T/T

 

 

B. Technical service

 

1. We calculate the capacity and recommend the best models.

 

2.We supply you the professional refrigeration technical support and electronic technical support for your installation, debugging and operation.

 

3. We supply the spare parts and technical support in and after the warranty time.

 

4. We supply the training course to your workers at our factory or site training if you need.

 

 

C. After-sales service

 

1. Technical support for your installation, operation and maintenance.

 

2. Standard warranty time: One years’warranty for heat pumps.

 

You can also pay for extended warranty or we can renegotiate the longer warranty period.

 

3. Spare parts and technical support at most economic prices after the warranty.

 

 

FAQ

 

Q1. Can I have a sample order for Heat pump or Water tank?

A: Yes, we welcome sample order to test and check quality. Mixed samples are acceptable.

 

Q2. What about the lead time?

A:Sample needs 3-10days, mass production time depend on the products'quantity.

 

Q3.Do you offer guarantee for the products?

A: Yes, 12 months since the heat pump depart from the port of loading (Refer to the Bill of Lading).

 

 

Certificsate we have got :

  • ISO 9001, ISO 14000
  • Our company has been inspected and certificate by EMC
  • CE And EN14511, EN 14825-ERP for heat pump exported to europe
  • Energy label for all heat pump models sold to oversea market
  • Testing laboratory calibrated by CNAS

Integrated Cooling And Heating System Geothermal Source Heat Pump MDS20D 1

 

 

Use

 

Business Organizations, Supermarket, shopping malls, shops, department store, star-rated hotels, restaurants, school, office;

 

Public Places, subway, airports, stations, bookstores, exhibition halls, stadiums, museums, commercial buildings, hospital;

 

Entertainments Movie theaters, clubs, bars, cafes, Internet bars, beauty shops

 

 

 Packaging Details
 Plywooden case