Product Details:
Place of Origin: Guangzhou China
Brand Name: Meeting
Certification: CE ISO CCC UKAS,ROHS
Model Number: MD60D
Payment & Shipping Terms:
Minimum Order Quantity: 5 PCS
Price: Negotiation
Packaging Details: Plywooden case
Delivery Time: 15 days
Payment Terms: T/T, WESTERN UNION
Supply Ability: 800/MONTH
Contact Now
Detailed Product Description
Material: Galvanized Sheet Contactor: Fuji Brand
Copper Thick: 0.8-1 Mm Compressor: With Oil Heater
Working Temperature: -15--45 Degree Insulation: Foam Pack Pipe And Stick On The Machine Innner
Display: LCD Figer Touch Control: Wifi Function Support
Power: 380v
High Light:

central air heat pump

,

residential geothermal heat pump

Meeting MD60D Air To Water Heat Pump Water Heater Connect With The End Floor Heating And Radiator For Home Heating Systems

 

 

 

Technology Specification

 

 

Features&Benefits

 

1. Easy installation with different water tanks

 

2. High efficiency with good performance

 

3. Famous brand compressor with R410a

 

4. Enlarged heat exchangers, high COP

 

5. Whisper quiet fan

 

6. Intelligent controller

 

7. Reverse cycle defrost with 4-way valve

 

8. Hydrophilic fin coil coating

 

9.Operation protection included

 

10. 100% factory tested

 

Advantages:
1.Generally cost less to operate than other types of conventional heating systems, save your electricity or gas bills.

2.Operate at a high efficiency with no flames, fumes, or flues; Water and electricity isolated.

3.With intelligent control systems which convenient and simple operation

4.Provide hot water no matter in cloudy day, snowy day or at night, unlike solar collectors which have to be facing the sun.

5.Transfer heat that’s already in the environment; Low CO2 emissions.

 

 

Internal porduct accessories

 

1 compressor:


The world-famous Copeland Flexible Scroll Compressor has functions such as low wear resistance,

 

long service life, over-current protection, phase loss protection, over-the-counter protection, strong liquid-impact resistance,

 

and high and low voltage protection. Copeland compressor built-in pressure relief valve in the body can

 

automatically relieve pressure when the high pressure is too high

 

 

2 Electronic expansion valve:


The introduction of the latest Japanese technology in conjunction with the company's control system has led

 

to the development of a unique electronic expansion valve control method and the use of digital technology

 

control to control the working fluid to achieve the best flow velocity effect, thereby increasing the COP value.

 

 

3 Condenstion heat exchanger:

 

In combination with the United States and the United States outside the threaded pipe technology,

 

successfully created a "spring" spiral tube new structure condenser. Better heat transfer, faster heat

 

transfer, and higher efficiency, minimize fouling, extend heat pump life and reduce maintenance

 

 

4 Electronic control system :

 

With powerful engineering supporting control functions , it can control circulating water pump, make-up

 

water , return water, water supply , electric heating , PID automatic defrosting, etc., making the control

 

easier. According to the needs of different projects, it can set various parameters by itself and realize

 

various water supply schemes . The entire system can be automated without special care.

 

 

5 Evaporation heat exchanger:


The use of hydrophilic membrane aluminum foil, even after long-term use


The use of a hydrophilic layer also does not result in oxidative detachment. this


The evaporator has a special advantage: Excellent skis performance


The more you can reduce the wind resistance, so that the condensate drains out quickly

outer.

 

Internally-threaded copper tube and corrugated aluminum foil structure
High evaporator efficiency.

 

 

 

 Payment service

 

1. T/T, 30% deposit, 70% balance.

 

 

After selling


1. We promise to offer free consulting call in 7~24 hours mode to solve the problems found in practice.


2. Products guarantee is 18~24 months from ex-factory date. Within 18months,if any components of your products damaged because of quality, we supply new replacement for free.


3. After the expiration of the quality assurance, we will continue to provide lifelong maintenance services, with just charging some cost price.

 

 

FAQ

 

Why us?

 

1. Timely Delivery, considerate sales after service

 

2. Many Years quality warranty,OEM service.

 

3. Top Craftmanship, All products 100% tested

 

4. Preferential freight by Famous shipping company

 

5. New Design,Very popular style products recommendation for your local market

 

 

Packaging & Shipment

1> Meeting heat pump can sure delivery heat pump within 5~20 working days as we warehouse stock condition.

 

2> Heat pump with strong plywood pallet , strong plywood box for loading, make sure no problem happen during rude transporattion .

 

3> All spare parts of the heat pump water heater will together loading into package , one time finished shipment to buyer.

 

4> Take video of the heat pump for buyer before package to 100% sure buyer get product same as order, no any different.

 

5> Meeting heat pump offer 100% test online, 5% test in Lab by 24 hour for one lot order (if not new model)

Packaging Details :Standard export packing -with plywoods case packages,OEM is available for Factory price heat pump water heaters

Delivery Time :15 work days after arrival of down payment

 

 

Air source heat pump parameters tables  

MODEL Unit MD10D
Rated heating capacity KW 3.5
Rated Cooling capacity   1.8
Hot water supply L/h 75
Average heating input power KW 0.75
Rated heating input current A 6
Rate outlet water temp 55
COP   3.65
Power V/Hz 220V/50
Noise Db(a) 48
Dimension W*D*H mm 1140×360×540
Packing size W*D*H mm 1200*400*710
Unit weight KG 75
Refrigerant   R417A
Working air temp range (-20℃)—45℃
compressor Type   Panasonic
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 1000L/h
Water pressure down Kpa 30
Pipe size DN 20
Max flat square meter M2 29
MODEL Unit MD15D
Rated heating capacity KW 5
Rated Cooling capacity   3
Hot water supply L/h 100
Average heating input power KW 1.25
Rated heating input current A 6
Rate outlet water temp 55
COP   3.65
Power V/Hz 220V/50
Noise Db(a) 48
Dimension W*D*H mm 1140×360×540
Packing size W*D*H mm 1200*400*710
Unit weight KG 75
Refrigerant   R417A
Working air temp range (-20℃)—45℃
compressor Type   Panasonic
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 1600L/h
Water pressure down Kpa 30
Pipe size DN 20
Max flat square meter M2 40
MODEL Unit MD20D
Rated heating capacity KW 7
Rated Cooling capacity   5
Hot water supply L/h 150
Average heating input power KW 1.84
Rated heating input current A 9
Max outlet water temp 60
COP   3.8
Power V/Hz 220V/50
Noise Db(a) 50
Dimension W*D*H mm 1140×360×540
Packing size W*D*H mm 1200*400*710
Unit weight KG 75
Refrigerant   R417A//R410
Working air temp range (-20℃)—45℃
compressor Type   Panasonic
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 2000L/h
Water pressure down Kpa 30
Pipe size DN 20
Max flat square meter M2 55
MODEL Unit MD30D
Rated heating capacity KW 12
Rated Cooling capacity   7
Hot water supply L/h 260
Average heating input power KW 3
Rated heating input current A 13/6
Max outlet water temp 60
COP   4
Power V/Hz 220V/380/50
Noise Db(a) 54
Dimension W*D*H mm 1120*490*710mm
Packing size W*D*H mm 1190*520*865mm
Unit weight KG 108
Refrigerant   R417A/R407C/R404A
Working air temp range   (-20℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 3000L/h
Water pressure down Kpa 40
Pipe size DN 25
Max flat square meter M2 100
MODEL Unit MD40D
Rated heating capacity KW 16
Rated Cooling capacity   10
Hot water supply L/h 360
Average heating input power KW 4
Rated heating input current A 9
Max outlet water temp 60
COP   4.2
Power V/Hz 380V/50
Noise Db(a) 55
Dimension W*D*H mm 1120*490*1270
Packing size W*D*H mm 1200*520*1425
Unit weight KG 160
Refrigerant   R417A/R407C/R404A
Working air temp range   (-20℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 4000L/h
Water pressure down Kpa 45
Pipe size DN 25
Max flat square meter M2 125
MODEL Unit MD50D
Rated heating capacity KW 18
Rated Cooling capacity   12
Hot water supply L/h 400
Average heating input power KW 4.4
Rated heating input current A 9
Max outlet water temp C 60
COP   4.2
Power V/Hz 380V/50
Noise Db(a) 55
Dimension W*D*H mm 1120*490*1270
Packing size W*D*H mm 1200*520*1425
Unit weight KG 160
Refrigerant   R417A/R407C/R404A
Working air temp range   (-20℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 5000L/h
Water pressure down Kpa 45
Pipe size DN 25
Max flat square meter M2 150
MODEL Unit MD60D
Rated heating capacity KW 21
Rated Cooling capacity   15
Hot water supply L/h 520
Average heating input power KW 5.68
Rated heating input current A 12
Max outlet water temp 60
COP   4.2
Power V/Hz 380/50
Noise Db(a) 60
Dimension W*D*H mm 1120*490*1270
Packing size W*D*H mm 1200*520*1425
Unit weight KG 210
Refrigerant   R417A/R407C/R404A
Working air temp range   (-15℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 6000
Water pressure down Kpa 48
Pipe size DN 25
Max flat square meter M2 175
MODEL Unit MD100D
Rated heating capacity KW 36
Rated Cooling capacity   24
Hot water supply L/h 800
Average heating input power KW 9.2
Rated heating input current A 18
Max outlet water temp 60
COP   4.2
Power V/Hz 380V/50
Noise Db(a) 60
Dimension W*D*H mm 1450×760×1060
Packing size W*D*H mm 1520*800*1230
Unit weight KG 289
Refrigerant   R417A/R407C/R404A
Working air temp range   (-20℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 10000L/h
Water pressure down Kpa 54
Pipe size DN 32
Max flat square meter M2 300
MODEL Unit MD150D
Rated heating capacity KW 42
Rated Cooling capacity   29
Hot water supply L/h 1200
Average heating input power KW 11
Rated heating input current A 18
Max outlet water temp 60
COP   4.2
Power V/Hz 380V/50
Noise Db(a) 60
Dimension W*D*H mm 1450×760×1060
Packing size W*D*H mm 1520*800*1230
Unit weight KG 320
Refrigerant   R417A/R407C/R404A
Working air temp range   (-20℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 15000L/h
Water pressure down Kpa 54
Pipe size DN 32
Max flat square meter M2 350
MODEL Unit MD200D
Rated heating capacity KW 72
Rated Cooling capacity   48
Hot water supply L/h 1590
Average heating input power KW 18.2
Rated heating input current A 35
Max outlet water temp 60
COP   4.5
Power V/Hz 380V/50
Noise Db(a) 65
Dimension W*D*H mm 2040×1100×2000
Packing size W*D*H mm 2080×1150×2130
Unit weight KG 650
Refrigerant   R417A/R407C/R404A
Working air temp range   (-20℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 20000L/h
Water pressure down Kpa 60
Pipe size DN 50
Max flat square meter M2 600
MODEL Unit MD300D
Rated heating capacity KW 88
Rated Cooling capacity   65
Hot water supply L/h 24000
Average heating input power KW 25
Rated heating input current A 45
Max outlet water temp 60
COP   4.5
Power V/Hz 380V/50
Noise Db(a) 68
Dimension W*D*H mm 2040×1100×2000
Packing size W*D*H mm 2080×1150×2130
Unit weight KG 650
Refrigerant   R417A/R407C
Working air temp range   (-20℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 30000L/h
Water pressure down Kpa 60