19 Years Professional Heat Pump Manufacturer!
Place of Origin: | Guangzhou China |
Brand Name: | Meeting |
Certification: | CE ISO CCC UKAS,ROHS |
Model Number: | MD60D |
Minimum Order Quantity: | 5 PCS |
---|---|
Price: | Negotiation |
Packaging Details: | Plywooden case |
Delivery Time: | 15 days |
Payment Terms: | T/T, WESTERN UNION |
Supply Ability: | 800/MONTH |
Material: | Galvanized Sheet | Contactor: | Fuji Brand |
---|---|---|---|
Copper Thick: | 0.8-1 Mm | Compressor: | With Oil Heater |
Working Temperature: | -15--45 Degree | Insulation: | Foam Pack Pipe And Stick On The Machine Innner |
Display: | LCD Figer Touch | Control: | Wifi Function Support |
Power: | 380v | ||
High Light: | central air heat pump,residential geothermal heat pump |
Meeting MD60D Air To Water Heat Pump Water Heater Connect With The End Floor Heating And Radiator For Home Heating Systems
Technology Specification
Features&Benefits
1. Easy installation with different water tanks
2. High efficiency with good performance
3. Famous brand compressor with R410a
4. Enlarged heat exchangers, high COP
5. Whisper quiet fan
6. Intelligent controller
7. Reverse cycle defrost with 4-way valve
8. Hydrophilic fin coil coating
9.Operation protection included
10. 100% factory tested
Internal porduct accessories
1 compressor:
The world-famous Copeland Flexible Scroll Compressor has functions such as low wear resistance,
long service life, over-current protection, phase loss protection, over-the-counter protection, strong liquid-impact resistance,
and high and low voltage protection. Copeland compressor built-in pressure relief valve in the body can
automatically relieve pressure when the high pressure is too high
2 Electronic expansion valve:
The introduction of the latest Japanese technology in conjunction with the company's control system has led
to the development of a unique electronic expansion valve control method and the use of digital technology
control to control the working fluid to achieve the best flow velocity effect, thereby increasing the COP value.
3 Condenstion heat exchanger:
In combination with the United States and the United States outside the threaded pipe technology,
successfully created a "spring" spiral tube new structure condenser. Better heat transfer, faster heat
transfer, and higher efficiency, minimize fouling, extend heat pump life and reduce maintenance
4 Electronic control system :
With powerful engineering supporting control functions , it can control circulating water pump, make-up
water , return water, water supply , electric heating , PID automatic defrosting, etc., making the control
easier. According to the needs of different projects, it can set various parameters by itself and realize
various water supply schemes . The entire system can be automated without special care.
5 Evaporation heat exchanger:
The use of hydrophilic membrane aluminum foil, even after long-term use
The use of a hydrophilic layer also does not result in oxidative detachment. this
The evaporator has a special advantage: Excellent skis performance
The more you can reduce the wind resistance, so that the condensate drains out quickly
outer.
Internally-threaded copper tube and corrugated aluminum foil structure
High evaporator efficiency.
Payment service
1. T/T, 30% deposit, 70% balance.
After selling
1. We promise to offer free consulting call in 7~24 hours mode to solve the problems found in practice.
2. Products guarantee is 18~24 months from ex-factory date. Within 18months,if any components of your products damaged because of quality, we supply new replacement for free.
3. After the expiration of the quality assurance, we will continue to provide lifelong maintenance services, with just charging some cost price.
FAQ
Why us?
1. Timely Delivery, considerate sales after service
2. Many Years quality warranty,OEM service.
3. Top Craftmanship, All products 100% tested
4. Preferential freight by Famous shipping company
5. New Design,Very popular style products recommendation for your local market
Packaging & Shipment
1> Meeting heat pump can sure delivery heat pump within 5~20 working days as we warehouse stock condition.
2> Heat pump with strong plywood pallet , strong plywood box for loading, make sure no problem happen during rude transporattion .
3> All spare parts of the heat pump water heater will together loading into package , one time finished shipment to buyer.
4> Take video of the heat pump for buyer before package to 100% sure buyer get product same as order, no any different.
5> Meeting heat pump offer 100% test online, 5% test in Lab by 24 hour for one lot order (if not new model)
Packaging Details :Standard export packing -with plywoods case packages,OEM is available for Factory price heat pump water heaters
Delivery Time :15 work days after arrival of down payment
Air source heat pump parameters tables
MODEL | Unit | MD10D | |
Rated heating capacity | KW | 3.5 | |
Rated Cooling capacity | 1.8 | ||
Hot water supply | L/h | 75 | |
Average heating input power | KW | 0.75 | |
Rated heating input current | A | 6 | |
Rate outlet water temp | ℃ | 55 | |
COP | 3.65 | ||
Power | V/Hz | 220V/50 | |
Noise | Db(a) | 48 | |
Dimension | W*D*H | mm | 1140×360×540 |
Packing size | W*D*H | mm | 1200*400*710 |
Unit weight | KG | 75 | |
Refrigerant | R417A | ||
Working air temp range | ℃ | (-20℃)—45℃ | |
compressor | Type | Panasonic | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 1000L/h | |
Water pressure down | Kpa | 30 | |
Pipe size | DN | 20 | |
Max flat square meter | M2 | 29 | |
MODEL | Unit | MD15D | |
Rated heating capacity | KW | 5 | |
Rated Cooling capacity | 3 | ||
Hot water supply | L/h | 100 | |
Average heating input power | KW | 1.25 | |
Rated heating input current | A | 6 | |
Rate outlet water temp | ℃ | 55 | |
COP | 3.65 | ||
Power | V/Hz | 220V/50 | |
Noise | Db(a) | 48 | |
Dimension | W*D*H | mm | 1140×360×540 |
Packing size | W*D*H | mm | 1200*400*710 |
Unit weight | KG | 75 | |
Refrigerant | R417A | ||
Working air temp range | ℃ | (-20℃)—45℃ | |
compressor | Type | Panasonic | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 1600L/h | |
Water pressure down | Kpa | 30 | |
Pipe size | DN | 20 | |
Max flat square meter | M2 | 40 | |
MODEL | Unit | MD20D | |
Rated heating capacity | KW | 7 | |
Rated Cooling capacity | 5 | ||
Hot water supply | L/h | 150 | |
Average heating input power | KW | 1.84 | |
Rated heating input current | A | 9 | |
Max outlet water temp | ℃ | 60 | |
COP | 3.8 | ||
Power | V/Hz | 220V/50 | |
Noise | Db(a) | 50 | |
Dimension | W*D*H | mm | 1140×360×540 |
Packing size | W*D*H | mm | 1200*400*710 |
Unit weight | KG | 75 | |
Refrigerant | R417A//R410 | ||
Working air temp range | ℃ | (-20℃)—45℃ | |
compressor | Type | Panasonic | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 2000L/h | |
Water pressure down | Kpa | 30 | |
Pipe size | DN | 20 | |
Max flat square meter | M2 | 55 | |
MODEL | Unit | MD30D | |
Rated heating capacity | KW | 12 | |
Rated Cooling capacity | 7 | ||
Hot water supply | L/h | 260 | |
Average heating input power | KW | 3 | |
Rated heating input current | A | 13/6 | |
Max outlet water temp | ℃ | 60 | |
COP | 4 | ||
Power | V/Hz | 220V/380/50 | |
Noise | Db(a) | 54 | |
Dimension | W*D*H | mm | 1120*490*710mm |
Packing size | W*D*H | mm | 1190*520*865mm |
Unit weight | KG | 108 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 3000L/h | |
Water pressure down | Kpa | 40 | |
Pipe size | DN | 25 | |
Max flat square meter | M2 | 100 | |
MODEL | Unit | MD40D | |
Rated heating capacity | KW | 16 | |
Rated Cooling capacity | 10 | ||
Hot water supply | L/h | 360 | |
Average heating input power | KW | 4 | |
Rated heating input current | A | 9 | |
Max outlet water temp | ℃ | 60 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 55 | |
Dimension | W*D*H | mm | 1120*490*1270 |
Packing size | W*D*H | mm | 1200*520*1425 |
Unit weight | KG | 160 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 4000L/h | |
Water pressure down | Kpa | 45 | |
Pipe size | DN | 25 | |
Max flat square meter | M2 | 125 | |
MODEL | Unit | MD50D | |
Rated heating capacity | KW | 18 | |
Rated Cooling capacity | 12 | ||
Hot water supply | L/h | 400 | |
Average heating input power | KW | 4.4 | |
Rated heating input current | A | 9 | |
Max outlet water temp | C | 60 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 55 | |
Dimension | W*D*H | mm | 1120*490*1270 |
Packing size | W*D*H | mm | 1200*520*1425 |
Unit weight | KG | 160 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 5000L/h | |
Water pressure down | Kpa | 45 | |
Pipe size | DN | 25 | |
Max flat square meter | M2 | 150 | |
MODEL | Unit | MD60D | |
Rated heating capacity | KW | 21 | |
Rated Cooling capacity | 15 | ||
Hot water supply | L/h | 520 | |
Average heating input power | KW | 5.68 | |
Rated heating input current | A | 12 | |
Max outlet water temp | ℃ | 60 | |
COP | 4.2 | ||
Power | V/Hz | 380/50 | |
Noise | Db(a) | 60 | |
Dimension | W*D*H | mm | 1120*490*1270 |
Packing size | W*D*H | mm | 1200*520*1425 |
Unit weight | KG | 210 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-15℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 6000 | |
Water pressure down | Kpa | 48 | |
Pipe size | DN | 25 | |
Max flat square meter | M2 | 175 | |
MODEL | Unit | MD100D | |
Rated heating capacity | KW | 36 | |
Rated Cooling capacity | 24 | ||
Hot water supply | L/h | 800 | |
Average heating input power | KW | 9.2 | |
Rated heating input current | A | 18 | |
Max outlet water temp | ℃ | 60 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 60 | |
Dimension | W*D*H | mm | 1450×760×1060 |
Packing size | W*D*H | mm | 1520*800*1230 |
Unit weight | KG | 289 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 10000L/h | |
Water pressure down | Kpa | 54 | |
Pipe size | DN | 32 | |
Max flat square meter | M2 | 300 | |
MODEL | Unit | MD150D | |
Rated heating capacity | KW | 42 | |
Rated Cooling capacity | 29 | ||
Hot water supply | L/h | 1200 | |
Average heating input power | KW | 11 | |
Rated heating input current | A | 18 | |
Max outlet water temp | ℃ | 60 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 60 | |
Dimension | W*D*H | mm | 1450×760×1060 |
Packing size | W*D*H | mm | 1520*800*1230 |
Unit weight | KG | 320 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 15000L/h | |
Water pressure down | Kpa | 54 | |
Pipe size | DN | 32 | |
Max flat square meter | M2 | 350 | |
MODEL | Unit | MD200D | |
Rated heating capacity | KW | 72 | |
Rated Cooling capacity | 48 | ||
Hot water supply | L/h | 1590 | |
Average heating input power | KW | 18.2 | |
Rated heating input current | A | 35 | |
Max outlet water temp | ℃ | 60 | |
COP | 4.5 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 65 | |
Dimension | W*D*H | mm | 2040×1100×2000 |
Packing size | W*D*H | mm | 2080×1150×2130 |
Unit weight | KG | 650 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 20000L/h | |
Water pressure down | Kpa | 60 | |
Pipe size | DN | 50 | |
Max flat square meter | M2 | 600 | |
MODEL | Unit | MD300D | |
Rated heating capacity | KW | 88 | |
Rated Cooling capacity | 65 | ||
Hot water supply | L/h | 24000 | |
Average heating input power | KW | 25 | |
Rated heating input current | A | 45 | |
Max outlet water temp | ℃ | 60 | |
COP | 4.5 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 68 | |
Dimension | W*D*H | mm | 2040×1100×2000 |
Packing size | W*D*H | mm | 2080×1150×2130 |
Unit weight | KG | 650 | |
Refrigerant | R417A/R407C | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 30000L/h | |
Water pressure down | Kpa | 60 | |
Pipe size | DN | 50 | |
Max flat square meter | M2 | 730 |
Contact Person: Ms. Alinna
Tel: +86 13922152741
Fax: 86-20
Save 75% Power Water To Air Heat Pump , Commercial Electric Air To Water Heat Pump
Meeting Electric Heat Pump System , 16 Kw Low Temperature Air Source Heat Pump
Household Electric Air Source Heat Pump Lower Heat Dissipate Long Operating Life
Electric Most Efficient Air Source Heat Pump , Ductless Heating And Cooling Units
Meeting water source heat pump water to water heat pumps can work good at extremly cold climate
Industrial Cold Climate Water Cooled Heat Pump , Geothermal Water To Water Heat Pump
High Cop Ground Source Heat Pump , High Water Temperature Geothermal Heat Pump
High Standard Water Source Heat Pump Wall Mounted EVI DC Inverter High Efficient
Swimming pool heat pump for water heating system.meeting 6P antiseptic chiller
Multifunction Swimming Pool Heat Pump Heating Capacity 380V / 220v 19kw 1120 * 490 * 1270mm
Most Efficient Pool Heat Pump , 380V 50kw Water Source Heat Pump Freestanding
Cold Water To Water Heat Pump Freestanding , Swimming Pool Air Source Heat Pump