19 Years Professional Heat Pump Manufacturer!
Place of Origin: | Guangzhou China |
Brand Name: | Meeting |
Certification: | CE ISO CCC UKAS,ROHS |
Model Number: | MD50D |
Minimum Order Quantity: | 5 PCS |
---|---|
Price: | Negotiation |
Packaging Details: | Plywooden case |
Delivery Time: | 15 days |
Payment Terms: | T/T, L/C WESTERN UNION |
Supply Ability: | 800/MONTH |
Material: | Galvanized Sheet | Contactor: | Fuji Brand |
---|---|---|---|
Copper Thick: | 1 Mm | Compressor: | With Oil Heater |
Working Temperature: | -20--45 Degree | Insulation: | Foam Pack Pipe And Stick On The Machine Innner |
Display: | LCD Figer Touch | Control: | Wifi Function Support |
Highlight: | low temperature air source heat pump,high temp heat pump |
Galvanized steel sheet 380V Air to water heat pump18KW side blowing heat pump for provide house heating
Technology Specification
Feature:
1. Economical operation
Generally cost less to operate than other types of conventional heating systems, save your electricity or gas bills.
2. Safety
Operate at a high efficiency with no flames, fumes, or flues; Water and electricity isolated
3. Environmental friendly
Transfer heat that’s already in the environment; Low CO2 emissions.
4. Easy operation
With intelligent control systems which convenient and simple operation
5. Constant hot water supply
Provide hot water no matter in cloudy day, snowy day or at night, unlike solar collectors which have to be facing the sun.
6. Wide application
Heat pump water heater can be applied to sanitary hot water, house heating .
Air source heat pump working principle
According to the principle of reverse Carnot cycle, the low-temperature and low-pressure liquid refrigerant
exchanges heat with the surrounding air in the evaporator, absorbs the heat Q1 in the air and evaporates
into a low-temperature and low-pressure gas state, the temperature of the refrigerant does not change
during evaporation, and the low-temperature and low-pressure gas refrigerant After entering the
compressor, the compressor is used to do work W. It is compressed into high-temperature and high-
pressure gas. Then it enters the condenser. In the condenser, it exchanges heat with indoor water. Part of
the heat Q2 of the high-temperature and high-pressure gaseous refrigerant is absorbed by the water. As the
temperature rises, the refrigerant radiates heat and condenses and turns into a high-temperature, high-
pressure liquid. During the condensation, the temperature of the refrigerant is constant and then enters the
expansion valve for throttling. Throttling is a process of rapid cooling, and the refrigerant turns into a low-
temperature and low-pressure liquid. This process is just like Contrary to the situation in the compressor,
the refrigerant after throttling enters into the evaporator for heat exchange, thereby realizing the entire
process of reverse Carnot. This cycle is continuous, and the air source heat pump can work continuously
and keep the water temperature constant. Increased
So Q2=Q1+W in this process
We have test every machine in here before leave the factory to take sure every machine working normally
A. Payment service
1. T/T
2. L/C (for container order only)
B. Technical service
1. We calculate the capacity and recommend the best models.
2.We supply you the professional refrigeration technical support and electronic technical support for your installation, debugging and operation.
3. We supply the spare parts and technical support in and after the warranty time.
4. We supply the training course to your workers at our factory if you need.
5. We can offer site training to your workers in your place which is negotiable.
C. After-sales service
1. Technical support for your installation, operation and maintenance.
2. Standard warranty time: One years’warranty for heat pumps
You can also pay for extended warranty or we can renegotiate the longer warranty period.
3. Spare parts and technical support at most economic prices after the warranty.
FAQ
Why us?
1. Timely Delivery, considerate sales after service
2. Many Years quality warranty,OEM service.
3. Top Craftmanship, All products 100% tested
4. Preferential freight by Famous shipping company
5. New Design,Very popular style products recommendation for your local market
|
Packaging & Shipment
1> Meeting heat pump can sure delivery heat pump within 5~20 working days as we warehouse stock condition.
2> Heat pump with strong plywood pallet , strong plywood box for loading, make sure no problem happen
during rude transporattion .
3> All spare parts of the heat pump water heater will together loading into package , one time finished shipment to buyer.
4> Take video of the heat pump for buyer before package to 100% sure buyer get product same as order, no any different.
5> Meeting heat pump offer 100% test online, 5% test in Lab by 24 hour for one lot order (if not new model)
Packaging Details :Standard export packing -with plywoods case packages,OEM is available for Factory price heat pump water heaters
Delivery Time :15 work days after arrival of down payment
ABOUT US
1). We were established in 2001.
2). We are a professional heat pump manufacturer, Located around Baiyun Air port
3). We are trading on Meeting Brand ,Meeting heat pump Well-know brand we operate in Europe market
4). Our company has been inspected and certificated by TUV and SGS.
5). We are the one of the first manufacturers whose heat pumps are with top COP gaining grants from Chinese government.
6). We passed ISO 9001 quality management system and ISO14000 environment protection system
7). Our testing laboratory can test heat pump up to 60KW heating capacity and create testing air temperature condition during -25DegC~45DegC,according to EN14511 standard.
8). Our leading products: Air to water heat pump , inverter heat pump, High water temperature heat pumps
Contact Person: Ms. Alinna
Tel: +86 13922152741
Fax: 86-20
Save 75% Power Water To Air Heat Pump , Commercial Electric Air To Water Heat Pump
Meeting Electric Heat Pump System , 16 Kw Low Temperature Air Source Heat Pump
Household Electric Air Source Heat Pump Lower Heat Dissipate Long Operating Life
Electric Most Efficient Air Source Heat Pump , Ductless Heating And Cooling Units
Meeting water source heat pump water to water heat pumps can work good at extremly cold climate
Industrial Cold Climate Water Cooled Heat Pump , Geothermal Water To Water Heat Pump
High Cop Ground Source Heat Pump , High Water Temperature Geothermal Heat Pump
High Standard Water Source Heat Pump Wall Mounted EVI DC Inverter High Efficient
Swimming pool heat pump for water heating system.meeting 6P antiseptic chiller
Multifunction Swimming Pool Heat Pump Heating Capacity 380V / 220v 19kw 1120 * 490 * 1270mm
Most Efficient Pool Heat Pump , 380V 50kw Water Source Heat Pump Freestanding
Cold Water To Water Heat Pump Freestanding , Swimming Pool Air Source Heat Pump