19 Years Professional Heat Pump Manufacturer!
Place of Origin: | Guangzhou China |
Brand Name: | Meeting |
Certification: | CE ISO CCC UKAS,ROHS |
Model Number: | MDY150D |
Minimum Order Quantity: | 5 PCS |
---|---|
Price: | Negotiation |
Packaging Details: | Plywooden case |
Delivery Time: | 15 days |
Payment Terms: | T/T, L/C WESTERN UNION |
Supply Ability: | 800/MONTH |
Materail: | Galvanized Steel Sheet | Contactor: | Fuji |
---|---|---|---|
Copper Pipe Thick: | 1 Mm | Compressor: | ZW Series ,With Crank Heating |
Working Temperature: | -20--45 Degree | Insulation: | Foam Pack Pipe And Stick On The Machine Innner |
Defrosting: | Automaticlly | Power: | 380V/50Hz |
Packing Size: | 1520*760*1190mm | Unit Weight: | 289KG |
Rated Heating Capacity: | 42KW | ||
Highlight: | electric heat pump for inground pool,inground pool heat pump |
Swimming Pool Heat Pump Lower Running Noise 42kw Heating capacity
Meeting lower running noise swimming pool heat pump water heater
Technology Specification
Product description
Heat pump used the heat from the air -20℃ below the cold coal recovery after compressed into a high temperature and high pressure refrigerant,
it needs to be heated by heat transfer of water or other medium,
make the heat efficiency of 400-500%.
Constant temperature swimming pool heat pump, Hot comfortable water for swimming
Swimming pool Parameters tables MDY10D-MDY300D
MODEL | Unit | MDY10D | |
Rated heating capacity | KW | 3.5 | |
Average heating input power | KW | 0.8 | |
Rated heating input current | A | 6 | |
Max outlet water temp | ℃ | 35 | |
COP | 3.8 | ||
Power | V/Hz | 220V/50 | |
Noise | Db(a) | 48 | |
Dimension | W*D*H | mm | 1140×360×538 |
Packing size | W*D*H | mm | 1180*380*680 |
Unit weight | KG | 70 | |
Refrigerant | R417A/R410 | ||
Working air temp range | ℃ | (-20℃)—45℃ | |
compressor | Type | Panasonic | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 1200L/h | |
Water pressure down | Kpa | 30 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY15D | |
Rated heating capacity | KW | 5.5 | |
Average heating input power | KW | 1.25 | |
Rated heating input current | A | 6 | |
Max outlet water temp | ℃ | 35 | |
COP | 3.8 | ||
Power | V/Hz | 220V/50 | |
Noise | Db(a) | 48 | |
Dimension | W*D*H | mm | 1140×360×539 |
Packing size | W*D*H | mm | 1180*380*680 |
Unit weight | KG | 70 | |
Refrigerant | R417A/R410 | ||
Working air temp range | ℃ | (-20℃)—45℃ | |
compressor | Type | Panasonic | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 1800L/h | |
Water pressure down | Kpa | 30 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY20D | |
Rated heating capacity | KW | 9 | |
Average heating input power | KW | 1.84 | |
Rated heating input current | A | 7 | |
Max outlet water temp | ℃ | 35 | |
COP | 3.8 | ||
Power | V/Hz | 220V/50 | |
Noise | Db(a) | 50 | |
Dimension | W*D*H | mm | 1140×360×540 |
Packing size | W*D*H | mm | 1180*380*680 |
Unit weight | KG | 75 | |
Refrigerant | R417A/R410 | ||
Working air temp range | ℃ | (-20℃)—45℃ | |
compressor | Type | Panasonic | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 3500L/h | |
Water pressure down | Kpa | 30 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY30D | |
Rated heating capacity | KW | 14 | |
Average heating input power | KW | 3 | |
Rated heating input current | A | 13/6 | |
Max outlet water temp | ℃ | 35 | |
COP | 4 | ||
Power | V/Hz | 220V/380/50 | |
Noise | Db(a) | 55 | |
Dimension | W*D*H | mm | 1120*490*790mm |
Packing size | W*D*H | mm | 1200*520*870mm |
Unit weight | KG | 110 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 5500L/h | |
Water pressure down | Kpa | 40 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY40D | |
Rated heating capacity | KW | 16 | |
Average heating input power | KW | 4 | |
Rated heating input current | A | 18/9 | |
Max outlet water temp | ℃ | 35 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 55 | |
Dimension | W*D*H | mm | 1120*490*1270 |
Packing size | W*D*H | mm | 1200*520*1440 |
Unit weight | KG | 160 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 6500L/h | |
Water pressure down | Kpa | 45 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY50D | |
Rated heating capacity | KW | 19 | |
Average heating input power | KW | 4.4 | |
Rated heating input current | A | 9 | |
Max outlet water temp | C | 35 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 55 | |
Dimension | W*D*H | mm | 1120*490*1270 |
Packing size | W*D*H | mm | 1200*520*1350 |
Unit weight | KG | 160 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20C)—45C | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 7500L/h | |
Water pressure down | Kpa | 45 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY60D | |
Rated heating capacity | KW | 26 | |
Average heating input power | KW | 6 | |
Rated heating input current | A | 12 | |
Max outlet water temp | ℃ | 35 | |
COP | 4.2 | ||
Power | V/Hz | 380/50 | |
Noise | Db(a) | 60 | |
Dimension | W*D*H | mm | 1120*490*1270 |
Packing size | W*D*H | mm | 1200*520*1350 |
Unit weight | KG | 210 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 9000L/h | |
Water pressure down | Kpa | 48 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY100D | |
Rated heating capacity | KW | 42 | |
Average heating input power | KW | 9.2 | |
Rated heating input current | A | 18 | |
Max outlet water temp | C | 35 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 60 | |
Dimension | W*D*H | mm | 1450×760×1060 |
Packing size | W*D*H | mm | 1520*760*1190mm |
Unit weight | KG | 289 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20C)—45C | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 15000L/h | |
Water pressure down | Kpa | 54 | |
Pipe size(water connection) | DN | 63 | |
MODEL | Unit | MDY150D | |
Rated heating capacity | KW | 50 | |
Rated Cooling capacity | KW | 37 | |
Average input power | KW | 11 | |
Rated input current | A | 24 | |
Max outlet water temp | C | 38 | |
COP | 4.5 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 60 | |
Dimension | W*D*H | mm | 1450×760×1060 |
Packing size | W*D*H | mm | 1520*760*1190mm |
Unit weight | KG | 320 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20C)—45C | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 18000L/h | |
Water pressure down | Kpa | 54 | |
Pipe size(water connection) | DN | 63 | |
MODEL | Unit | MDY200D | |
Rated heating capacity | KW | 84 | |
Average heating input power | KW | 19 | |
Rated heating input current | A | 35 | |
Max outlet water temp | ℃ | 35 | |
COP | 4.5 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 65 | |
Dimension | W*D*H | mm | 1990*980*2080 |
Packing size | W*D*H | mm | 2080×1150×2130 |
Unit weight | KG | 650 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 28000L/h | |
Water pressure down | Kpa | 60 | |
Pipe size(water connection) | DN | 63 | |
MODEL | Unit | MDY300D | |
Rated heating capacity | KW | 100 | |
Average heating input power | KW | 25 | |
Rated heating input current | A | 45 | |
Max outlet water temp | ℃ | 35 | |
COP | 4.5 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 68 | |
Dimension | W*D*H | mm | 1990*980*2080 |
Packing size | W*D*H | mm | 2080×1150×2130 |
Unit weight | KG | 650 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 45000L/h | |
Water pressure down | Kpa | 60 | |
Pipe size(water connection) | DN | 63 |
Swimming pool heat pump heating:
1. High efficiency & energy saving
2. Safe & Comfort
3. Convenient & widely to use
4. Swimming Pool Heat Pump heating:
Swimming Pool Heat Pump heating:
* Long operating life
Using the advanced titanium in PVC or Nickel – copper in PVC shell & tube heat exchangers, which can resist corrosion from chlorine in the water.
* Economical and high efficiency
Using the more efficient heat pump technology, compared to other ordinary hot water equipment (for example, combustion oil boiler, comb-ussion gas boiler and electrical boiler),it reduces operation cost by 65%~80%,moreover,it produces little pollution for environment.
* Innovative design, easy installation and replacement.
Mono block (single unit conclusion) design, the unit is remarkable compact and easy to install.
* Advanced control
It is extremely easy to control the swimming pump unit because of the built-in computer with its intelligent control and LCD display.
* Use safely
Swimming pool/bath/hotel heat pump water heater
Advantage feature
A: Pool: Length, width, depth.
B: Ambient temperature.
C: Water input and output temperature.
Easy to use, once set, always have hot/cool water
Life span is 12-15 years
1 years
Contact Person: Ms. Alinna
Tel: +86 13922152741
Fax: 86-20
Save 75% Power Water To Air Heat Pump , Commercial Electric Air To Water Heat Pump
Meeting Electric Heat Pump System , 16 Kw Low Temperature Air Source Heat Pump
Household Electric Air Source Heat Pump Lower Heat Dissipate Long Operating Life
Electric Most Efficient Air Source Heat Pump , Ductless Heating And Cooling Units
Meeting water source heat pump water to water heat pumps can work good at extremly cold climate
Industrial Cold Climate Water Cooled Heat Pump , Geothermal Water To Water Heat Pump
High Cop Ground Source Heat Pump , High Water Temperature Geothermal Heat Pump
High Standard Water Source Heat Pump Wall Mounted EVI DC Inverter High Efficient
Swimming pool heat pump for water heating system.meeting 6P antiseptic chiller
Multifunction Swimming Pool Heat Pump Heating Capacity 380V / 220v 19kw 1120 * 490 * 1270mm
Most Efficient Pool Heat Pump , 380V 50kw Water Source Heat Pump Freestanding
Cold Water To Water Heat Pump Freestanding , Swimming Pool Air Source Heat Pump