19 Years Professional Heat Pump Manufacturer!
Place of Origin: | Guangzhou China |
Brand Name: | Meeting |
Certification: | CE ISO CCC UKAS,ROHS |
Model Number: | MD300D |
Minimum Order Quantity: | 5 PCS |
---|---|
Price: | Negotiation |
Packaging Details: | Plywooden case |
Delivery Time: | 15 days |
Payment Terms: | T/T, L/C WESTERN UNION |
Supply Ability: | 800/MONTH |
Materail: | Galvanized Steel Sheet | Contactor: | Fuji |
---|---|---|---|
Copper Pipe Thick: | 1 Mm | Compressor: | ZW Series ,With Crank Heating |
Working Temperature: | -20--45 Degree | Insulation: | Foam Pack Pipe And Stick On The Machine Innner |
Defrosting: | Automaticlly | Use: | Swimming Pool, Spa |
Installation: | Freestanding | ||
Highlight: | swimming pool air source heat pump,inground pool heat pump |
100kW Commercial Air to water Juteng Swimming pool Air source Heat Pump High COP Top type pool equipment
Technology Specification
Advantage
*Constant heating and cooling function, applicable to swimming pool, Spa or fish cultivation.
*Advanced corrosion resistance Titanium heat exchanger, virtually impervious to water chemistry damage.
*World famous Japanese brand compressor.
*Digital LCD display wire control panel, controls water temperature to within 1-5°C difference from set point.
*On-off timing function, no human attendance is required for operation once started.
*Insufficient water flow protection & high/low pressure protection.
*Auto defrosting with 4-way valve, ensure reliably running at low ambient temperature.
*Warms your pool or SPA with the reliability and efficiency can also cool your pool and SPA
during hot summer season.
1) Swimming pool heat pump, Up to 80% energy saving, compared with conventional water heaters such as gas/oil boilers and electricity resistance water heaters
2) LCD display control panel
3) Automatic unit on/off timer clock. No human attendance is required once unit is started
4)Insufficient water flow and high/low pressure protection
5) Users can regulate the outlet water temperature in accordance with different project requirements.
6) Strong defrosting function and able to work reliably at cold ambient air temperature
7) Corrosion resistant titanium heat exchanger
8) Cold water function optional and suitable for hot areas where pool water need to cooled in summer
Swimming pool heat pump parameters tables
MODEL | Unit | MDY10D | |
Rated heating capacity | KW | 3.5 | |
Average heating input power | KW | 0.8 | |
Rated heating input current | A | 6 | |
Max outlet water temp | ℃ | 35 | |
COP | 3.8 | ||
Power | V/Hz | 220V/50 | |
Noise | Db(a) | 48 | |
Dimension | W*D*H | mm | 1140×360×538 |
Packing size | W*D*H | mm | 1180*380*680 |
Unit weight | KG | 70 | |
Refrigerant | R417A/R410 | ||
Working air temp range | ℃ | (-20℃)—45℃ | |
compressor | Type | Panasonic | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 1200L/h | |
Water pressure down | Kpa | 30 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY15D | |
Rated heating capacity | KW | 5.5 | |
Average heating input power | KW | 1.25 | |
Rated heating input current | A | 6 | |
Max outlet water temp | ℃ | 35 | |
COP | 3.8 | ||
Power | V/Hz | 220V/50 | |
Noise | Db(a) | 48 | |
Dimension | W*D*H | mm | 1140×360×539 |
Packing size | W*D*H | mm | 1180*380*680 |
Unit weight | KG | 70 | |
Refrigerant | R417A/R410 | ||
Working air temp range | ℃ | (-20℃)—45℃ | |
compressor | Type | Panasonic | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 1800L/h | |
Water pressure down | Kpa | 30 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY20D | |
Rated heating capacity | KW | 9 | |
Average heating input power | KW | 1.84 | |
Rated heating input current | A | 7 | |
Max outlet water temp | ℃ | 35 | |
COP | 3.8 | ||
Power | V/Hz | 220V/50 | |
Noise | Db(a) | 50 | |
Dimension | W*D*H | mm | 1140×360×540 |
Packing size | W*D*H | mm | 1180*380*680 |
Unit weight | KG | 75 | |
Refrigerant | R417A/R410 | ||
Working air temp range | ℃ | (-20℃)—45℃ | |
compressor | Type | Panasonic | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 3500L/h | |
Water pressure down | Kpa | 30 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY30D | |
Rated heating capacity | KW | 14 | |
Average heating input power | KW | 3 | |
Rated heating input current | A | 13/6 | |
Max outlet water temp | ℃ | 35 | |
COP | 4 | ||
Power | V/Hz | 220V/380/50 | |
Noise | Db(a) | 55 | |
Dimension | W*D*H | mm | 1120*490*790mm |
Packing size | W*D*H | mm | 1200*520*870mm |
Unit weight | KG | 110 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 5500L/h | |
Water pressure down | Kpa | 40 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY40D | |
Rated heating capacity | KW | 16 | |
Average heating input power | KW | 4 | |
Rated heating input current | A | 18/9 | |
Max outlet water temp | ℃ | 35 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 55 | |
Dimension | W*D*H | mm | 1120*490*1270 |
Packing size | W*D*H | mm | 1200*520*1440 |
Unit weight | KG | 160 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 6500L/h | |
Water pressure down | Kpa | 45 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY50D | |
Rated heating capacity | KW | 19 | |
Average heating input power | KW | 4.4 | |
Rated heating input current | A | 9 | |
Max outlet water temp | C | 35 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 55 | |
Dimension | W*D*H | mm | 1120*490*1270 |
Packing size | W*D*H | mm | 1200*520*1350 |
Unit weight | KG | 160 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20C)—45C | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 7500L/h | |
Water pressure down | Kpa | 45 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY60D | |
Rated heating capacity | KW | 26 | |
Average heating input power | KW | 6 | |
Rated heating input current | A | 12 | |
Max outlet water temp | ℃ | 35 | |
COP | 4.2 | ||
Power | V/Hz | 380/50 | |
Noise | Db(a) | 60 | |
Dimension | W*D*H | mm | 1120*490*1270 |
Packing size | W*D*H | mm | 1200*520*1350 |
Unit weight | KG | 210 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 9000L/h | |
Water pressure down | Kpa | 48 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY100D | |
Rated heating capacity | KW | 42 | |
Average heating input power | KW | 9.2 | |
Rated heating input current | A | 18 | |
Max outlet water temp | C | 35 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 60 | |
Dimension | W*D*H | mm | 1450×760×1060 |
Packing size | W*D*H | mm | 1520*760*1190mm |
Unit weight | KG | 289 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20C)—45C | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 15000L/h | |
Water pressure down | Kpa | 54 | |
Pipe size(water connection) | DN | 63 | |
MODEL | Unit | MDY150D | |
Rated heating capacity | KW | 50 | |
Rated Cooling capacity | KW | 37 | |
Average input power | KW | 11 | |
Rated input current | A | 24 | |
Max outlet water temp | C | 38 | |
COP | 4.5 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 60 | |
Dimension | W*D*H | mm | 1450×760×1060 |
Packing size | W*D*H | mm | 1520*760*1190mm |
Unit weight | KG | 320 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20C)—45C | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 18000L/h | |
Water pressure down | Kpa | 54 | |
Pipe size(water connection) | DN | 63 | |
MODEL | Unit | MDY200D | |
Rated heating capacity | KW | 84 | |
Average heating input power | KW | 19 | |
Rated heating input current | A | 35 | |
Max outlet water temp | ℃ | 35 | |
COP | 4.5 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 65 | |
Dimension | W*D*H | mm | 1990*980*2080 |
Packing size | W*D*H | mm | 2080×1150×2130 |
Unit weight | KG | 650 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 28000L/h | |
Water pressure down | Kpa | 60 | |
Pipe size(water connection) | DN | 63 | |
MODEL | Unit | MDY300D | |
Rated heating capacity | KW | 100 | |
Average heating input power | KW | 25 | |
Rated heating input current | A | 45 | |
Max outlet water temp | ℃ | 35 | |
COP | 4.5 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 68 | |
Dimension | W*D*H | mm | 1990*980*2080 |
Packing size | W*D*H | mm | 2080×1150×2130 |
Unit weight | KG | 650 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 45000L/h | |
Water pressure down | Kpa | 60 | |
Pipe size(water connection) | DN | 63 |
Packaging & Delivery
Packaging Details: export wooden packing
Delivery Time: 15-30 days
Specifications
Swimming pool heat pump heating:
1. High efficiency & energy saving
2. Safe & Comfort
3. Convenient & widely to use
4. Swimming Pool Heat Pump heating:
|
|
|
Use
Business Organizations
Supermarket, shopping malls, shops, department store, star-rated
hotels, restaurants, school, office;
Public Places
subway, airports, stations, bookstores, exhibition halls, stadiums, museums, commercial buildings, hospital;
Entertainments Movie theaters, clubs, bars, cafes, Internet bars, beauty shops
Our Services
1. After installation, our company will be responsible for problems caused by quality of production or raw material except the damageable spare parts of heat pump caused by incorrect man-made operation during the guarantee period.
2. Intelligent Controlling service system will be avoid the long distance of the after sale problem. Wherever are you, our engineer can be controlled your equipment, when some questions occur on the equipment. Just tell us what number will be shown on the screen, then the engineer will be solve the problem.
3. We accept OEM, ODM and customization.
4. 24*7 after sales service. You will get satisfied service.
5. We have More than 17years production and sales experience; Professional sales team.
Contact Person: Ms. Alinna
Tel: +86 13922152741
Fax: 86-20
Save 75% Power Water To Air Heat Pump , Commercial Electric Air To Water Heat Pump
Meeting Electric Heat Pump System , 16 Kw Low Temperature Air Source Heat Pump
Household Electric Air Source Heat Pump Lower Heat Dissipate Long Operating Life
Electric Most Efficient Air Source Heat Pump , Ductless Heating And Cooling Units
Meeting water source heat pump water to water heat pumps can work good at extremly cold climate
Industrial Cold Climate Water Cooled Heat Pump , Geothermal Water To Water Heat Pump
High Cop Ground Source Heat Pump , High Water Temperature Geothermal Heat Pump
High Standard Water Source Heat Pump Wall Mounted EVI DC Inverter High Efficient
Swimming pool heat pump for water heating system.meeting 6P antiseptic chiller
Multifunction Swimming Pool Heat Pump Heating Capacity 380V / 220v 19kw 1120 * 490 * 1270mm
Most Efficient Pool Heat Pump , 380V 50kw Water Source Heat Pump Freestanding
Cold Water To Water Heat Pump Freestanding , Swimming Pool Air Source Heat Pump