Guangzhou Jin Lun Electric Equipment Co.,Ltd

18 Years Professional Heat Pump Manufacturer!

 

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsSwimming Pool Heat Pump

Coated Matel Swimming Pool Heat Pump / 100kw High COP Water Chiller

Coated Matel Swimming Pool Heat Pump / 100kw High COP Water Chiller

    • Coated Matel Swimming Pool Heat Pump  / 100kw High COP Water Chiller
    • Coated Matel Swimming Pool Heat Pump  / 100kw High COP Water Chiller
  • Coated Matel Swimming Pool Heat Pump  / 100kw High COP Water Chiller

    Product Details:

    Place of Origin: Guangzhou China
    Brand Name: Meeting
    Certification: CE ISO CCC UKAS,ROHS
    Model Number: MDY300D

    Payment & Shipping Terms:

    Minimum Order Quantity: 5 PCS
    Price: Negotiation
    Packaging Details: Plywooden case
    Delivery Time: 15 days
    Payment Terms: T/T, L/C WESTERN UNION
    Supply Ability: 800/MONTH
    Contact Now
    Detailed Product Description
    Materail: Coated Matel Contactor: Fuji Brand
    Copper Thick: 1 Mm Compressor: With Oil Heater
    Display: LCD Finger Touch Control: Wifi Function Support
    Reted Heating Capacity: 100KW Power Supply: 380V/ 50Hz
    Power Input: 25KW Noise: 68Db(a)

    Swimming Pool Heat Pump Heating 100kw High COP water chiller

     

    Technology Specification

     

     

    Swimming pool heat pump

     

    1. Swimming pool heater pump can be installed in many environments, including a constant temperature

    swimming pool, sauna constant hot water system, villa, or to supply hot water at home.


    2.Pure titanium pool heat exchanger, anti-corrosion and durable.


    3. Durable coating in white or metal-grey.


    4. Auto-defrost function available.


    5. Easy installation, connect the inlet /outlet water pipe and then enjoy it.

     

     

    Swimming pool heat pump parameter tables 

     

     

    MODEL Unit MDY10D
    Rated heating capacity KW 3.5
    Average heating input power KW 0.8
    Rated heating input current A 6
    Max outlet water temp 35
    COP   3.8
    Power V/Hz 220V/50
    Noise Db(a) 48
    Dimension W*D*H mm 1140×360×538
    Packing size W*D*H mm 1180*380*680
    Unit weight KG 70
    Refrigerant   R417A/R410
    Working air temp range (-20℃)—45℃
    compressor Type   Panasonic
    Air source heat exchanger Type   Finned heat exchange
    Fan Type   axial flow fan
    Hot water side heat exchange Type   Titanium heat exchanger
    Water flow L/H 1200L/h
    Water pressure down Kpa 30
    Pipe size(water connection) DN 50
    MODEL Unit MDY15D
    Rated heating capacity KW 5.5
    Average heating input power KW 1.25
    Rated heating input current A 6
    Max outlet water temp 35
    COP   3.8
    Power V/Hz 220V/50
    Noise Db(a) 48
    Dimension W*D*H mm 1140×360×539
    Packing size W*D*H mm 1180*380*680
    Unit weight KG 70
    Refrigerant   R417A/R410
    Working air temp range (-20℃)—45℃
    compressor Type   Panasonic
    Air source heat exchanger Type   Finned heat exchange
    Fan Type   axial flow fan
    Hot water side heat exchange Type   Titanium heat exchanger
    Water flow L/H 1800L/h
    Water pressure down Kpa 30
    Pipe size(water connection) DN 50
    MODEL Unit MDY20D
    Rated heating capacity KW 9
    Average heating input power KW 1.84
    Rated heating input current A 7
    Max outlet water temp 35
    COP   3.8
    Power V/Hz 220V/50
    Noise Db(a) 50
    Dimension W*D*H mm 1140×360×540
    Packing size W*D*H mm 1180*380*680
    Unit weight KG 75
    Refrigerant   R417A/R410
    Working air temp range (-20℃)—45℃
    compressor Type   Panasonic
    Air source heat exchanger Type   Finned heat exchange
    Fan Type   axial flow fan
    Hot water side heat exchange Type   Titanium heat exchanger
    Water flow L/H 3500L/h
    Water pressure down Kpa 30
    Pipe size(water connection) DN 50
    MODEL Unit MDY30D
    Rated heating capacity KW 14
    Average heating input power KW 3
    Rated heating input current A 13/6
    Max outlet water temp 35
    COP   4
    Power V/Hz 220V/380/50
    Noise Db(a) 55
    Dimension W*D*H mm 1120*490*790mm
    Packing size W*D*H mm 1200*520*870mm
    Unit weight KG 110
    Refrigerant   R417A/R407C/R410A
    Working air temp range   (-20℃)—45℃
    compressor Type   Copeland
    Air source heat exchanger Type   Finned heat exchange
    Fan Type   axial flow fan
    Hot water side heat exchange Type   Titanium heat exchanger
    Water flow L/H 5500L/h
    Water pressure down Kpa 40
    Pipe size(water connection) DN 50
    MODEL Unit MDY40D
    Rated heating capacity KW 16
    Average heating input power KW 4
    Rated heating input current A 18/9
    Max outlet water temp 35
    COP   4.2
    Power V/Hz 380V/50
    Noise Db(a) 55
    Dimension W*D*H mm 1120*490*1270
    Packing size W*D*H mm 1200*520*1440
    Unit weight KG 160
    Refrigerant   R417A/R407C/R410A
    Working air temp range   (-20℃)—45℃
    compressor Type   Copeland
    Air source heat exchanger Type   Finned heat exchange
    Fan Type   axial flow fan
    Hot water side heat exchange Type   Titanium heat exchanger
    Water flow L/H 6500L/h
    Water pressure down Kpa 45
    Pipe size(water connection) DN 50
    MODEL Unit MDY50D
    Rated heating capacity KW 19
    Average heating input power KW 4.4
    Rated heating input current A 9
    Max outlet water temp C 35
    COP   4.2
    Power V/Hz 380V/50
    Noise Db(a) 55
    Dimension W*D*H mm 1120*490*1270
    Packing size W*D*H mm 1200*520*1350
    Unit weight KG 160
    Refrigerant   R417A/R407C/R410A
    Working air temp range   (-20C)—45C
    compressor Type   Copeland
    Air source heat exchanger Type   Finned heat exchange
    Fan Type   axial flow fan
    Hot water side heat exchange Type   Titanium heat exchanger
    Water flow L/H 7500L/h
    Water pressure down Kpa 45
    Pipe size(water connection) DN 50
    MODEL Unit MDY60D
    Rated heating capacity KW 26
    Average heating input power KW 6
    Rated heating input current A 12
    Max outlet water temp 35
    COP   4.2
    Power V/Hz 380/50
    Noise Db(a) 60
    Dimension W*D*H mm 1120*490*1270
    Packing size W*D*H mm 1200*520*1350
    Unit weight KG 210
    Refrigerant   R417A/R407C/R410A
    Working air temp range   (-20℃)—45℃
    compressor Type   Copeland
    Air source heat exchanger Type   Finned heat exchange
    Fan Type   axial flow fan
    Hot water side heat exchange Type   Titanium heat exchanger
    Water flow L/H 9000L/h
    Water pressure down Kpa 48
    Pipe size(water connection) DN 50
    MODEL Unit MDY100D
    Rated heating capacity KW 42
    Average heating input power KW 9.2
    Rated heating input current A 18
    Max outlet water temp C 35
    COP   4.2
    Power V/Hz 380V/50
    Noise Db(a) 60
    Dimension W*D*H mm 1450×760×1060
    Packing size W*D*H mm 1520*760*1190mm
    Unit weight KG 289
    Refrigerant   R417A/R407C/R410A
    Working air temp range   (-20C)—45C
    compressor Type   Copeland
    Air source heat exchanger Type   Finned heat exchange
    Fan Type   axial flow fan
    Hot water side heat exchange Type   Titanium heat exchanger
    Water flow L/H 15000L/h
    Water pressure down Kpa 54
    Pipe size(water connection) DN 63
    MODEL Unit MDY150D
    Rated heating capacity KW 50
    Rated Cooling capacity KW 37
    Average input power KW 11
    Rated input current A 24
    Max outlet water temp C 38
    COP   4.5
    Power V/Hz 380V/50
    Noise Db(a) 60
    Dimension W*D*H mm 1450×760×1060
    Packing size W*D*H mm 1520*760*1190mm
    Unit weight KG 320
    Refrigerant   R417A/R407C/R410A
    Working air temp range   (-20C)—45C
    compressor Type   Copeland
    Air source heat exchanger Type   Finned heat exchange
    Fan Type   axial flow fan
    Hot water side heat exchange Type   Titanium heat exchanger
    Water flow L/H 18000L/h
    Water pressure down Kpa 54
    Pipe size(water connection) DN 63
    MODEL Unit MDY200D
    Rated heating capacity KW 84
    Average heating input power KW 19
    Rated heating input current A 35
    Max outlet water temp 35
    COP   4.5
    Power V/Hz 380V/50
    Noise Db(a) 65
    Dimension W*D*H mm 1990*980*2080
    Packing size W*D*H mm 2080×1150×2130
    Unit weight KG 650
    Refrigerant   R417A/R407C/R410A
    Working air temp range   (-20℃)—45℃
    compressor Type   Copeland
    Air source heat exchanger Type   Finned heat exchange
    Fan Type   axial flow fan
    Hot water side heat exchange Type   Titanium heat exchanger
    Water flow L/H 28000L/h
    Water pressure down Kpa 60
    Pipe size(water connection) DN 63
    MODEL Unit MDY300D
    Rated heating capacity KW 100
    Average heating input power KW 25
    Rated heating input current A 45
    Max outlet water temp 35
    COP   4.5
    Power V/Hz 380V/50
    Noise Db(a) 68
    Dimension W*D*H mm 1990*980*2080
    Packing size W*D*H mm 2080×1150×2130
    Unit weight KG 650
    Refrigerant   R417A/R407C/R410A
    Working air temp range   (-20℃)—45℃
    compressor Type   Copeland
    Air source heat exchanger Type   Finned heat exchange
    Fan Type   axial flow fan
    Hot water side heat exchange Type   Titanium heat exchanger
    Water flow L/H 45000L/h
    Water pressure down Kpa 60
    Pipe size(water connection) DN 63

     

     

     

    Specifications

    Swimming pool heat pump heating:


    1. High efficiency & energy saving


    2. Safe & Comfort


    3. Convenient & widely to use

     

    4. Swimming Pool Heat Pump heating:

    • Swimming pool heat pump can save you up to 80% in operating cost whether you just want to extend your swimming season or swim all year round in a warm comfortable pool.
    •  
    • With special designed heat exchangers, Swimming pool heat pump can give you the perfect water temperature without a big increase in your power bill, our swimming pool heat pump is a perfect selection to your in-ground swimming pool or sea.
    •  
    • The product can be widely installed at any kind of places, such as constant temperature swimming pools, sauna constant hot water system and supplying domestic hot water to home.

    Coated Matel Swimming Pool Heat Pump  / 100kw High COP Water Chiller

     

    Coated Matel Swimming Pool Heat Pump  / 100kw High COP Water Chiller

     

    Our Services

     

    1. After installation, our company will be responsible for problems caused by quality of production or raw material except the damageable spare parts of heat pump caused by incorrect man-made operation during the guarantee period.

     

    2. Intelligent Controlling service system will be avoid the long distance of the after sale problem. Wherever are you, our engineer can be controlled your equipment, when some questions occur on the equipment. Just tell us what number will be shown on the screen, then the engineer will be solve the problem.

     

    3. We accept OEM, ODM and customization.

     

    4. 24*7 after sales service. You will get satisfied service.

     

    5. We have More than 17years production and sales experience; Professional sales team.

     

    • FAQ
    • What is your advantage, comparing with other water heaters?
    •  
      • A: Avoiding electric water heater leakage, dry, high power consumption.

      • B: Avoiding the drawbacks of gas water heater, such as producing harmful gases,
      • Fits and starts etc.
      •  
      • C: Energy efficient, safety and environmental protection, all-weather operation, easy to use.

     

    • What details do you need?

    A: Pool: Length, width, depth.

     

    B: Ambient temperature.

     

    C: Water input and output temperature.

     

    • Will it be too trouble to use air water heater?

    Easy to use, once set, always have hot/cool water

     

    • How long is the life of air water heater

    Life span is 12-15 years

     

    • .How many years guarantee?