Home ProductsAir To Water Heat Pump

Economical Heat Pump Air Conditioner , Air Source Heat Pump System For Subway / Airports

Good quality Electric Air Source Heat Pump for sales
Gold supplier , I recived an air source heat pump last week,lt look great,they are very good quality,we will increase more order next time!Thank you!

—— Ms Emma

The goods arrived today the heat pump is of good quality, it is easy to use, the heating effect is good, and the service is also well Thanks!

—— Mr Weber

I'm Online Chat Now

Economical Heat Pump Air Conditioner , Air Source Heat Pump System For Subway / Airports

China Economical Heat Pump Air Conditioner , Air Source Heat Pump System For Subway / Airports supplier
Economical Heat Pump Air Conditioner , Air Source Heat Pump System For Subway / Airports supplier Economical Heat Pump Air Conditioner , Air Source Heat Pump System For Subway / Airports supplier Economical Heat Pump Air Conditioner , Air Source Heat Pump System For Subway / Airports supplier Economical Heat Pump Air Conditioner , Air Source Heat Pump System For Subway / Airports supplier Economical Heat Pump Air Conditioner , Air Source Heat Pump System For Subway / Airports supplier

Large Image :  Economical Heat Pump Air Conditioner , Air Source Heat Pump System For Subway / Airports

Product Details:

Place of Origin: Guangzhou China
Brand Name: Meeting
Certification: CE ISO CCC UKAS,ROHS
Model Number: MD200D

Payment & Shipping Terms:

Minimum Order Quantity: 5 PCS
Price: Negotiation
Packaging Details: Plywooden case
Delivery Time: 15 days
Payment Terms: T/T, L/C WESTERN UNION
Supply Ability: 800/MONTH
Contact Now
Detailed Product Description
Material: Galvanized Sheet Contactor: Fuji Brand
Copper Thick: 1 Mm Compressor: With Oil Heater
Working Temperature: -20--45 Degree Insulation: Foam Pack Pipe And Stick On The Machine Innner
Display: LCD Figer Touch Control: Wifi Function Support

Meeting MD200D Galvanized steel sheet 380V Air to water heat pump 72KW side blow heat pump for provide water heating

Technology Specification

 

Feature:

1. Economical operation

Generally cost less to operate than other types of conventional heating systems, save your electricity or gas bills.

2. Safety

Operate at a high efficiency with no flames, fumes, or flues; Water and electricity isolated

3. Environmental friendly

Transfer heat that’s already in the environment; Low CO2 emissions.

4. Easy operation

With intelligent control systems which convenient and simple operation

5. Constant hot water supply

Provide hot water no matter in cloudy day, snowy day or at night, unlike solar collectors which have to be facing the sun.

6. Wide application

7. Heat pump water heater can be applied to sanitary hot water, house heating .

 

Air source heat pump working principle

According to the principle of reverse Carnot cycle, the low-temperature and low-pressure liquid refrigerant exchanges heat with the surrounding air in the evaporator, absorbs the heat Q1 in the air and evaporates into a low-temperature and low-pressure gas state, the temperature of the refrigerant does not change during evaporation, and the low-temperature and low-pressure gas refrigerant After entering the compressor, the compressor is used to do work W. It is compressed into high-temperature and high-pressure gas. Then it enters the condenser. In the condenser, it exchanges heat with indoor water. Part of the heat Q2 of the high-temperature and high-pressure gaseous refrigerant is absorbed by the water. As the temperature rises, the refrigerant radiates heat and condenses and turns into a high-temperature, high-pressure liquid. During the condensation, the temperature of the refrigerant is constant and then enters the expansion valve for throttling. Throttling is a process of rapid cooling, and the refrigerant turns into a low-temperature and low-pressure liquid. This process is just like Contrary to the situation in the compressor, the refrigerant after throttling enters into the evaporator for heat exchange, thereby realizing the entire process of reverse Carnot. This cycle is continuous, and the air source heat pump can work continuously and keep the water temperature constant. Increased

So Q2=Q1+W in this process

 

A. Payment service

1. T/T

2. L/C (for container order only)

 

B. Technical service

1. We calculate the capacity and recommend the best models.

2.We supply you the professional refrigeration technical support and electronic technical support for your installation, debugging and operation.

3. We supply the spare parts and technical support in and after the warranty time.

4. We supply the training course to your workers at our factory if you need.

5. We can offer site training to your workers in your place which is negotiable.

 

C. After-sales service

1. Technical support for your installation, operation and maintenance.

2. Standard warranty time: One years’warranty for heat pumps

You can also pay for extended warranty or we can renegotiate the longer warranty period.

3. Spare parts and technical support at most economic prices after the warranty.

 

FAQ

Why us?

1. Timely Delivery, considerate sales after service

2.  Many Years quality warranty,OEM service.

3. Top Craftmanship, All products 100% tested

4. Preferential freight by Famous shipping company

5. New Design,Very popular style products recommendation for your local market

 

Packaging & Shipment

1> Meeting heat pump can sure delivery heat pump within 5~20 working days as we warehouse stock condition.

2> Heat pump with strong plywood pallet , strong plywood box for loading, make sure no problem happen during rude transporattion .

3> All spare parts of the heat pump water heater will together loading into package , one time finished shipment to buyer.

4> Take video of the heat pump for buyer before package to 100% sure buyer get product same as order, no any different.

5> Meeting heat pump offer 100% test online, 5% test in Lab by 24 hour for one lot order (if not new model)

Packaging Details :Standard export packing -with plywoods case packages,OEM is available for Factory price heat pump water heaters

Delivery Time :15 work days after arrival of down payment

 

 

MODEL Unit MD10D
Rated heating capacity KW 3.5
Rated Cooling capacity   1.8
Hot water supply L/h 75
Average heating input power KW 0.75
Rated heating input current A 6
Rate outlet water temp 55
COP   3.65
Power V/Hz 220V/50
Noise Db(a) 48
Dimension W*D*H mm 1140×360×540
Packing size W*D*H mm 1200*400*710
Unit weight KG 75
Refrigerant   R417A
Working air temp range (-20℃)—45℃
compressor Type   Panasonic
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 1000L/h
Water pressure down Kpa 30
Pipe size DN 20
Max flat square meter M2 29
MODEL Unit MD15D
Rated heating capacity KW 5
Rated Cooling capacity   3
Hot water supply L/h 100
Average heating input power KW 1.25
Rated heating input current A 6
Rate outlet water temp 55
COP   3.65
Power V/Hz 220V/50
Noise Db(a) 48
Dimension W*D*H mm 1140×360×540
Packing size W*D*H mm 1200*400*710
Unit weight KG 75
Refrigerant   R417A
Working air temp range (-20℃)—45℃
compressor Type   Panasonic
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 1600L/h
Water pressure down Kpa 30
Pipe size DN 20
Max flat square meter M2 40
MODEL Unit MD20D
Rated heating capacity KW 7
Rated Cooling capacity   5
Hot water supply L/h 150
Average heating input power KW 1.84
Rated heating input current A 9
Max outlet water temp 60
COP   3.8
Power V/Hz 220V/50
Noise Db(a) 50
Dimension W*D*H mm 1140×360×540
Packing size W*D*H mm 1200*400*710
Unit weight KG 75
Refrigerant   R417A//R410
Working air temp range (-20℃)—45℃
compressor Type   Panasonic
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 2000L/h
Water pressure down Kpa 30
Pipe size DN 20
Max flat square meter M2 55
MODEL Unit MD30D
Rated heating capacity KW 12
Rated Cooling capacity   7
Hot water supply L/h 260
Average heating input power KW 3
Rated heating input current A 13/6
Max outlet water temp 60
COP   4
Power V/Hz 220V/380/50
Noise Db(a) 54
Dimension W*D*H mm 1120*490*710mm
Packing size W*D*H mm 1190*520*865mm
Unit weight KG 108
Refrigerant   R417A/R407C/R404A
Working air temp range   (-20℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 3000L/h
Water pressure down Kpa 40
Pipe size DN 25
Max flat square meter M2 100
MODEL Unit MD40D
Rated heating capacity KW 16
Rated Cooling capacity   10
Hot water supply L/h 360
Average heating input power KW 4
Rated heating input current A 9
Max outlet water temp 60
COP   4.2
Power V/Hz 380V/50
Noise Db(a) 55
Dimension W*D*H mm 1120*490*1270
Packing size W*D*H mm 1200*520*1425
Unit weight KG 160
Refrigerant   R417A/R407C/R404A
Working air temp range   (-20℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 4000L/h
Water pressure down Kpa 45
Pipe size DN 25
Max flat square meter M2 125
MODEL Unit MD50D
Rated heating capacity KW 18
Rated Cooling capacity   12
Hot water supply L/h 400
Average heating input power KW 4.4
Rated heating input current A 9
Max outlet water temp C 60
COP   4.2
Power V/Hz 380V/50
Noise Db(a) 55
Dimension W*D*H mm 1120*490*1270
Packing size W*D*H mm 1200*520*1425
Unit weight KG 160
Refrigerant   R417A/R407C/R404A
Working air temp range   (-20℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 5000L/h
Water pressure down Kpa 45
Pipe size DN 25
Max flat square meter M2 150
MODEL Unit MD60D
Rated heating capacity KW 21
Rated Cooling capacity   15
Hot water supply L/h 520
Average heating input power KW 5.68
Rated heating input current A 12
Max outlet water temp 60
COP   4.2
Power V/Hz 380/50
Noise Db(a) 60
Dimension W*D*H mm 1120*490*1270
Packing size W*D*H mm 1200*520*1425
Unit weight KG 210
Refrigerant   R417A/R407C/R404A
Working air temp range   (-20℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 6000
Water pressure down Kpa 48
Pipe size DN 25
Max flat square meter M2 175
MODEL Unit MD100D
Rated heating capacity KW 36
Rated Cooling capacity   24
Hot water supply L/h 800
Average heating input power KW 9.2
Rated heating input current A 18
Max outlet water temp 60
COP   4.2
Power V/Hz 380V/50
Noise Db(a) 60
Dimension W*D*H mm 1450×760×1060
Packing size W*D*H mm 1520*800*1230
Unit weight KG 289
Refrigerant   R417A/R407C/R404A
Working air temp range   (-20℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 10000L/h
Water pressure down Kpa 54
Pipe size DN 32
Max flat square meter M2 300
MODEL Unit MD150D
Rated heating capacity KW 42
Rated Cooling capacity   29
Hot water supply L/h 1200
Average heating input power KW 11
Rated heating input current A 18
Max outlet water temp 60
COP   4.2
Power V/Hz 380V/50
Noise Db(a) 60
Dimension W*D*H mm 1450×760×1060
Packing size W*D*H mm 1520*800*1230
Unit weight KG 320
Refrigerant   R417A/R407C/R404A
Working air temp range   (-20℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 15000L/h
Water pressure down Kpa 54
Pipe size DN 32
Max flat square meter M2 350
MODEL Unit MD200D
Rated heating capacity KW 72
Rated Cooling capacity   48
Hot water supply L/h 1590
Average heating input power KW 18.2
Rated heating input current A 35
Max outlet water temp 60
COP   4.5
Power V/Hz 380V/50
Noise Db(a) 65
Dimension W*D*H mm 2040×1100×2000
Packing size W*D*H mm 2080×1150×2130
Unit weight KG 650
Refrigerant   R417A/R407C/R404A
Working air temp range   (-20℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 20000L/h
Water pressure down Kpa 60
Pipe size DN 50
Max flat square meter M2 600
MODEL Unit MD300D
Rated heating capacity KW 88
Rated Cooling capacity   65
Hot water supply L/h 24000
Average heating input power KW 25
Rated heating input current A 45
Max outlet water temp 60
COP   4.5
Power V/Hz 380V/50
Noise Db(a) 68
Dimension W*D*H mm 2040×1100×2000
Packing size W*D*H mm 2080×1150×2130
Unit weight KG 650
Refrigerant   R417A/R407C
Working air temp range   (-20℃)—45℃
compressor Type   Copeland
Air source heat exchanger Type   Finned heat exchange
Fan Type   axial flow fan
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 30000L/h
Water pressure down Kpa 60
Pipe size DN 50
Max flat square meter M2 730

 

 

ABOUT US

1).We were established in 2001.

2).We are a professional heat pump manufacturer, Located around Baiyun Air port

3). We are trading on Meeting Brand ,Meeting heat pump Well-know brand we operate in Europe market

4). Our company has been inspected and certificated by TUV and SGS.

5). We are the one of the first manufacturers whose heat pumps are with top COP gaining grants from Chinese government.

6).We passed ISO 9001 quality management system and ISO14000 environment protection system

7). Our testing laboratory can test heat pump up to 60KW heating capacity and create testing air temperature condition during -25DegC~45DegC,according to EN14511 standard.

9). Our leading products: Air to water heat pump , DC inverter heat pump, High water temperature heat pumps

 

 

Contact Details
Guangzhou Jin Lun Electric Equipment Co.,Ltd

Contact Person: Steven

Send your inquiry directly to us (0 / 3000)