    Product Details:

    Place of Origin: Guangzhou China
    Brand Name: Meeting
    Certification: CE ISO CCC UKAS,ROHS
    Model Number: MD60D

    Payment & Shipping Terms:

    Minimum Order Quantity: 5 PCS
    Price: Negotiation
    Packaging Details: Plywooden case
    Delivery Time: 15 days
    Payment Terms: T/T, WESTERN UNION
    Supply Ability: 800/MONTH
    Contact Now
    Detailed Product Description
    Material: Galvanized Sheet Contactor: Fuji Brand
    Copper Thick: 0.8-1 Mm Compressor: With Oil Heater
    Working Temperature: -15--45 Degree Insulation: Foam Pack Pipe And Stick On The Machine Innner
    Display: LCD Figer Touch Control: Wifi Function Support
    Power: 380v
    High Light:

    central air heat pump

    ,

    residential geothermal heat pump

    Meeting MD60D Air To Water Heat Pump Water Heater Connect With The End Floor Heating And Radiator For Home Heating Systems

     

     

     

    Technology Specification

     

     

    Features&Benefits

     

    1. Easy installation with different water tanks

     

    2. High efficiency with good performance

     

    3. Famous brand compressor with R410a

     

    4. Enlarged heat exchangers, high COP

     

    5. Whisper quiet fan

     

    6. Intelligent controller

     

    7. Reverse cycle defrost with 4-way valve

     

    8. Hydrophilic fin coil coating

     

    9.Operation protection included

     

    10. 100% factory tested

     

    Advantages:
    1.Generally cost less to operate than other types of conventional heating systems, save your electricity or gas bills.

    2.Operate at a high efficiency with no flames, fumes, or flues; Water and electricity isolated.

    3.With intelligent control systems which convenient and simple operation

    4.Provide hot water no matter in cloudy day, snowy day or at night, unlike solar collectors which have to be facing the sun.

    5.Transfer heat that’s already in the environment; Low CO2 emissions.

     

     

    Internal porduct accessories

     

    1 compressor:


    The world-famous Copeland Flexible Scroll Compressor has functions such as low wear resistance,

     

    long service life, over-current protection, phase loss protection, over-the-counter protection, strong liquid-impact resistance,

     

    and high and low voltage protection. Copeland compressor built-in pressure relief valve in the body can

     

    automatically relieve pressure when the high pressure is too high

     

     

    2 Electronic expansion valve:


    The introduction of the latest Japanese technology in conjunction with the company's control system has led

     

    to the development of a unique electronic expansion valve control method and the use of digital technology

     

    control to control the working fluid to achieve the best flow velocity effect, thereby increasing the COP value.

     

     

    3 Condenstion heat exchanger:

     

    In combination with the United States and the United States outside the threaded pipe technology,

     

    successfully created a "spring" spiral tube new structure condenser. Better heat transfer, faster heat

     

    transfer, and higher efficiency, minimize fouling, extend heat pump life and reduce maintenance

     

     

    4 Electronic control system :

     

    With powerful engineering supporting control functions , it can control circulating water pump, make-up

     

    water , return water, water supply , electric heating , PID automatic defrosting, etc., making the control

     

    easier. According to the needs of different projects, it can set various parameters by itself and realize

     

    various water supply schemes . The entire system can be automated without special care.

     

     

    5 Evaporation heat exchanger:


    The use of hydrophilic membrane aluminum foil, even after long-term use


    The use of a hydrophilic layer also does not result in oxidative detachment. this


    The evaporator has a special advantage: Excellent skis performance


    The more you can reduce the wind resistance, so that the condensate drains out quickly

    outer.

     

    Internally-threaded copper tube and corrugated aluminum foil structure
    High evaporator efficiency.

     

     

     

     Payment service

     

    1. T/T, 30% deposit, 70% balance.

     

     

    After selling


    1. We promise to offer free consulting call in 7~24 hours mode to solve the problems found in practice.


    2. Products guarantee is 18~24 months from ex-factory date. Within 18months,if any components of your products damaged because of quality, we supply new replacement for free.


    3. After the expiration of the quality assurance, we will continue to provide lifelong maintenance services, with just charging some cost price.

     

     

    FAQ

     

    Why us?

     

    1. Timely Delivery, considerate sales after service

     

    2. Many Years quality warranty,OEM service.

     

    3. Top Craftmanship, All products 100% tested

     

    4. Preferential freight by Famous shipping company

     

    5. New Design,Very popular style products recommendation for your local market

     

     

    Packaging & Shipment

    1> Meeting heat pump can sure delivery heat pump within 5~20 working days as we warehouse stock condition.

     

    2> Heat pump with strong plywood pallet , strong plywood box for loading, make sure no problem happen during rude transporattion .

     

    3> All spare parts of the heat pump water heater will together loading into package , one time finished shipment to buyer.

     

    4> Take video of the heat pump for buyer before package to 100% sure buyer get product same as order, no any different.

     

    5> Meeting heat pump offer 100% test online, 5% test in Lab by 24 hour for one lot order (if not new model)

    Packaging Details :Standard export packing -with plywoods case packages,OEM is available for Factory price heat pump water heaters

    Delivery Time :15 work days after arrival of down payment

     

     

    Air source heat pump parameters tables  

    MODEL Unit MD10D
    Rated heating capacity KW 3.5
    Rated Cooling capacity   1.8
    Hot water supply L/h 75
    Average heating input power KW 0.75
    Rated heating input current A 6
    Rate outlet water temp 55
    COP   3.65
    Power V/Hz 220V/50
    Noise Db(a) 48
    Dimension W*D*H mm 1140×360×540
    Packing size W*D*H mm 1200*400*710
    Unit weight KG 75
    Refrigerant   R417A
    Working air temp range (-20℃)—45℃
    compressor Type   Panasonic
    Air source heat exchanger Type   Finned heat exchange
    Fan Type   axial flow fan
    Hot water side heat exchange Type   Coil heat exchanger
    Water flow L/H 1000L/h
    Water pressure down Kpa 30
    Pipe size DN 20
    Max flat square meter M2 29
    MODEL Unit MD15D
    Rated heating capacity KW 5
    Rated Cooling capacity   3
    Hot water supply L/h 100
    Average heating input power KW 1.25
    Rated heating input current A 6
    Rate outlet water temp 55
    COP   3.65
    Power V/Hz 220V/50
    Noise Db(a) 48
    Dimension W*D*H mm 1140×360×540
    Packing size W*D*H mm 1200*400*710
    Unit weight KG 75
    Refrigerant   R417A
    Working air temp range (-20℃)—45℃
    compressor Type   Panasonic
    Air source heat exchanger Type   Finned heat exchange
    Fan Type   axial flow fan
    Hot water side heat exchange Type   Coil heat exchanger
    Water flow L/H 1600L/h
    Water pressure down Kpa 30
    Pipe size DN 20
    Max flat square meter M2 40
    MODEL Unit MD20D
    Rated heating capacity KW 7
    Rated Cooling capacity   5
    Hot water supply L/h 150
    Average heating input power KW 1.84
    Rated heating input current A 9
    Max outlet water temp 60
    COP   3.8
    Power V/Hz 220V/50
    Noise Db(a) 50
    Dimension W*D*H mm 1140×360×540
    Packing size W*D*H mm 1200*400*710
    Unit weight KG 75
    Refrigerant   R417A//R410
    Working air temp range (-20℃)—45℃
    compressor Type   Panasonic
    Air source heat exchanger Type   Finned heat exchange
    Fan Type   axial flow fan
    Hot water side heat exchange Type   Coil heat exchanger
    Water flow L/H 2000L/h
    Water pressure down Kpa 30
    Pipe size DN 20
    Max flat square meter M2 55
    MODEL Unit MD30D
    Rated heating capacity KW 12
    Rated Cooling capacity   7
    Hot water supply L/h 260
    Average heating input power KW 3
    Rated heating input current A 13/6
    Max outlet water temp 60
    COP   4
    Power V/Hz 220V/380/50
    Noise Db(a) 54
    Dimension W*D*H mm 1120*490*710mm
    Packing size W*D*H mm 1190*520*865mm
    Unit weight KG 108
    Refrigerant   R417A/R407C/R404A
    Working air temp range   (-20℃)—45℃
    compressor Type   Copeland
    Air source heat exchanger Type   Finned heat exchange
    Fan Type   axial flow fan
    Hot water side heat exchange Type   Coil heat exchanger
    Water flow L/H 3000L/h
    Water pressure down Kpa 40
    Pipe size DN 25
    Max flat square meter M2 100
    MODEL Unit MD40D
    Rated heating capacity KW 16
    Rated Cooling capacity   10
    Hot water supply L/h 360
    Average heating input power KW 4
    Rated heating input current A 9
    Max outlet water temp 60
    COP   4.2
    Power V/Hz 380V/50
    Noise Db(a) 55
    Dimension W*D*H mm 1120*490*1270
    Packing size W*D*H mm 1200*520*1425
    Unit weight KG 160
    Refrigerant   R417A/R407C/R404A
    Working air temp range   (-20℃)—45℃
    compressor Type   Copeland
    Air source heat exchanger Type   Finned heat exchange
    Fan Type   axial flow fan
    Hot water side heat exchange Type   Coil heat exchanger
    Water flow L/H 4000L/h
    Water pressure down Kpa 45
    Pipe size DN 25
    Max flat square meter M2 125
    MODEL Unit MD50D
    Rated heating capacity KW 18
    Rated Cooling capacity   12
    Hot water supply L/h 400
    Average heating input power KW 4.4
    Rated heating input current A 9
    Max outlet water temp C 60
    COP   4.2
    Power V/Hz 380V/50
    Noise Db(a) 55
    Dimension W*D*H mm 1120*490*1270
    Packing size W*D*H mm 1200*520*1425
    Unit weight KG 160
    Refrigerant   R417A/R407C/R404A
    Working air temp range   (-20℃)—45℃
    compressor Type   Copeland
    Air source heat exchanger Type   Finned heat exchange
    Fan Type   axial flow fan
    Hot water side heat exchange Type   Coil heat exchanger
    Water flow L/H 5000L/h
    Water pressure down Kpa 45
    Pipe size DN 25
    Max flat square meter M2 150
    MODEL Unit MD60D
    Rated heating capacity KW 21
    Rated Cooling capacity   15
    Hot water supply L/h 520
    Average heating input power KW 5.68
    Rated heating input current A 12
    Max outlet water temp 60
    COP   4.2
    Power V/Hz 380/50
    Noise Db(a) 60
    Dimension W*D*H mm 1120*490*1270
    Packing size W*D*H mm 1200*520*1425
    Unit weight KG 210
    Refrigerant   R417A/R407C/R404A
    Working air temp range   (-15℃)—45℃
    compressor Type   Copeland
    Air source heat exchanger Type   Finned heat exchange
    Fan Type   axial flow fan
    Hot water side heat exchange Type   Coil heat exchanger
    Water flow L/H 6000
    Water pressure down Kpa 48
    Pipe size DN 25
    Max flat square meter M2 175
    MODEL Unit MD100D
    Rated heating capacity KW 36
    Rated Cooling capacity   24
    Hot water supply L/h 800
    Average heating input power KW 9.2
    Rated heating input current A 18
    Max outlet water temp 60
    COP   4.2
    Power V/Hz 380V/50
    Noise Db(a) 60
    Dimension W*D*H mm 1450×760×1060
    Packing size W*D*H mm 1520*800*1230
    Unit weight KG 289
    Refrigerant   R417A/R407C/R404A
    Working air temp range   (-20℃)—45℃
    compressor Type   Copeland
    Air source heat exchanger Type   Finned heat exchange
    Fan Type   axial flow fan
    Hot water side heat exchange Type   Coil heat exchanger
    Water flow L/H 10000L/h
    Water pressure down Kpa 54
    Pipe size DN 32
    Max flat square meter M2 300
    MODEL Unit MD150D
    Rated heating capacity KW 42
    Rated Cooling capacity   29
    Hot water supply L/h 1200
    Average heating input power KW 11
    Rated heating input current A 18
    Max outlet water temp 60
    COP   4.2
    Power V/Hz 380V/50
    Noise Db(a) 60
    Dimension W*D*H mm 1450×760×1060
    Packing size W*D*H mm 1520*800*1230
    Unit weight KG 320
    Refrigerant   R417A/R407C/R404A
    Working air temp range   (-20℃)—45℃
    compressor Type   Copeland
    Air source heat exchanger Type   Finned heat exchange
    Fan Type   axial flow fan
    Hot water side heat exchange Type   Coil heat exchanger
    Water flow L/H 15000L/h
    Water pressure down Kpa 54
    Pipe size DN 32
    Max flat square meter M2 350
    MODEL Unit MD200D
    Rated heating capacity KW 72
    Rated Cooling capacity   48
    Hot water supply L/h 1590
    Average heating input power KW 18.2
    Rated heating input current A 35
    Max outlet water temp 60
    COP   4.5
    Power V/Hz 380V/50
    Noise Db(a) 65
    Dimension W*D*H mm 2040×1100×2000
    Packing size W*D*H mm 2080×1150×2130
    Unit weight KG 650
    Refrigerant   R417A/R407C/R404A
    Working air temp range   (-20℃)—45℃
    compressor Type   Copeland
    Air source heat exchanger Type   Finned heat exchange
    Fan Type   axial flow fan
    Hot water side heat exchange Type   Coil heat exchanger
    Water flow L/H 20000L/h
    Water pressure down Kpa 60
    Pipe size DN 50
    Max flat square meter M2 600
    MODEL Unit MD300D
    Rated heating capacity KW 88
    Rated Cooling capacity   65
    Hot water supply L/h 24000
    Average heating input power KW 25
    Rated heating input current A 45
    Max outlet water temp 60
    COP   4.5
    Power V/Hz 380V/50
    Noise Db(a) 68
    Dimension W*D*H mm 2040×1100×2000
    Packing size W*D*H mm 2080×1150×2130
    Unit weight KG 650
    Refrigerant   R417A/R407C
    Working air temp range   (-20℃)—45℃
    compressor Type   Copeland
    Air source heat exchanger Type   Finned heat exchange
    Fan Type   axial flow fan
    Hot water side heat exchange Type   Coil heat exchanger
    Water flow L/H 30000L/h
    Water pressure down Kpa 60
    Pipe size DN 50
    Max flat square meter M2 730

     

    MD60D Air To Water Heat Pump Water Heater Connect With End Floor Heating & Radiator For Home Heating System 0

    Contact Details
    Guangzhou Jin Lun Electric Equipment Co.,Ltd

    Contact Person: Ms. Alinna

    Tel: +86 13922152741

    Fax: 86-20

    Send your inquiry directly to us (0 / 3000)

    Other Products