Guangzhou Jin Lun Electric Equipment Co.,Ltd

19 Years Professional Heat Pump Manufacturer!

 

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsHome Heat Pump

220V 50HZ Home Heat Pump Heating + Domestic Hot Water 5kw Reted Heating Capacity

220V 50HZ Home Heat Pump Heating + Domestic Hot Water 5kw Reted Heating Capacity

    • 220V 50HZ Home Heat Pump Heating + Domestic Hot Water 5kw Reted Heating Capacity
    • 220V 50HZ Home Heat Pump Heating + Domestic Hot Water 5kw Reted Heating Capacity
    • 220V 50HZ Home Heat Pump Heating + Domestic Hot Water 5kw Reted Heating Capacity
    • 220V 50HZ Home Heat Pump Heating + Domestic Hot Water 5kw Reted Heating Capacity
  • 220V 50HZ Home Heat Pump Heating + Domestic Hot Water 5kw Reted Heating Capacity

    Product Details:

    Place of Origin: Guangzhou China
    Brand Name: Meeting
    Certification: CE ISO CCC UKAS,ROHS
    Model Number: MD15D

    Payment & Shipping Terms:

    Minimum Order Quantity: 5 PCS
    Price: Negotiation
    Packaging Details: Plywooden case
    Delivery Time: 15 days
    Payment Terms: T/T, L/C WESTERN UNION
    Supply Ability: 800/MONTH
    Contact Now
    Detailed Product Description
    Material: Galvanized Sheet Contactor: Fuji Brand
    Copper Thick: 1 Mm Compressor: With Oil Heater
    Working Temperature: -20--45 Degree Insulation: Foam Pack Pipe And Stick On The Machine Innner
    Display: LCD Figer Touch Control: Wifi Function Support
    Reted Heating Capacity: 5KW Packing Size: 1200*400*710MM
    Refrigerant: R417A Power: 220V/ 50HZ
    Noise: 48Db(a) Use: Residential
    High Light:

    central air heat pump

    ,

    residential geothermal heat pump

    Home heat pump Heating + domestic hot water 5kw reted heating capacity

     

    Technology Specification

     

     

    1.Description :

     

    Air source  heat pump is a kind of high energy saving water heater and green products.

    In the system, there is a water cycle between indoor unit and outdoor unit. In outdoor unit, there is a refrigerant cycle, we call it reverse Carnot cycle, it consists of four component,

     

     

    Feature:

     

    1. Economical operation

    Generally cost less to operate than other types of conventional heating systems, save your electricity or gas bills.

     

    2. Safety

    Operate at a high efficiency with no flames, fumes, or flues; Water and electricity isolated

     

    3. Environmental friendly

    Transfer heat that’s already in the environment; Low CO2 emissions.

     

    4. Easy operation

    With intelligent control systems which convenient and simple operation

     

    5. Constant hot water supply

    Provide hot water no matter in cloudy day, snowy day or at night, unlike solar collectors which have to be facing the sun.

     

    6. Wide application

    Heat pump water heater can be applied to sanitary hot water, house heating .

     

     

    Working Principle:

    In the system, there is a refrigerant cycle, we call it reverse Carnot cycle, it consists of four component,

    Following is air source heat pump working principle.

     

    Air source heat pump Working principle picture  

    220V 50HZ Home Heat Pump Heating + Domestic Hot Water 5kw Reted Heating Capacity 0

     

     

    220V 50HZ Home Heat Pump Heating + Domestic Hot Water 5kw Reted Heating Capacity 1

     

     

     Payment service

    1. T/T

    2. L/C (for container order only)

     

     

     

    FAQ

     

    Why us?

    1. Timely Delivery, considerate sales after service

     

    2. Many Years quality warranty,OEM service.

     

    3. Top Craftmanship, All products 100% tested

     

    4. Preferential freight by Famous shipping company

     

    5. New Design,Very popular style products recommendation for your local market

     

     

    Packaging & Shipment

    1> Meeting heat pump can sure delivery heat pump within 5~20 working days as we warehouse stock condition.

     

    2> Heat pump with strong plywood pallet , strong plywood box for loading, make sure no problem happen during rude transporattion .

     

    3> All spare parts of the heat pump water heater will together loading into package , one time finished shipment to buyer.

     

    4> Take video of the heat pump for buyer before package to 100% sure buyer get product same as order, no any different.

     

    5> Meeting heat pump offer 100% test online, 5% test in Lab by 24 hour for one lot order (if not new model)

    Packaging Details :Standard export packing -with plywoods case packages,OEM is available for Factory price heat pump water heaters

    Delivery Time :15 work days after arrival of down payment

     

     

     

    MODEL Unit MD10D
    Rated heating capacity KW 3.5
    Rated Cooling capacity   1.8
    Hot water supply L/h 75
    Average heating input power KW 0.75
    Rated heating input current A 6
    Rate outlet water temp 55
    COP   3.65
    Power V/Hz 220V/50
    Noise Db(a) 48
    Dimension W*D*H mm 1140×360×540
    Packing size W*D*H mm 1200*400*710
    Unit weight KG 75
    Refrigerant   R417A
    Working air temp range (-20℃)—45℃
    compressor Type   Panasonic
    Air source heat exchanger Type   Finned heat exchange
    Fan Type   axial flow fan
    Hot water side heat exchange Type   Coil heat exchanger
    Water flow L/H 1000L/h
    Water pressure down Kpa 30
    Pipe size DN 20
    Max flat square meter M2 29
    MODEL Unit MD15D
    Rated heating capacity KW 5
    Rated Cooling capacity   3
    Hot water supply L/h 100
    Average heating input power KW 1.25
    Rated heating input current A 6
    Rate outlet water temp 55
    COP   3.65
    Power V/Hz 220V/50
    Noise Db(a) 48
    Dimension W*D*H mm 1140×360×540
    Packing size W*D*H mm 1200*400*710
    Unit weight KG 75
    Refrigerant   R417A
    Working air temp range (-20℃)—45℃
    compressor Type   Panasonic
    Air source heat exchanger Type   Finned heat exchange
    Fan Type   axial flow fan
    Hot water side heat exchange Type   Coil heat exchanger
    Water flow L/H 1600L/h
    Water pressure down Kpa 30
    Pipe size DN 20
    Max flat square meter M2 40
    MODEL Unit MD20D
    Rated heating capacity KW 7
    Rated Cooling capacity   5
    Hot water supply L/h 150
    Average heating input power KW 1.84
    Rated heating input current A 9
    Max outlet water temp 60
    COP   3.8
    Power V/Hz 220V/50
    Noise Db(a) 50
    Dimension W*D*H mm 1140×360×540
    Packing size W*D*H mm 1200*400*710
    Unit weight KG 75
    Refrigerant   R417A//R410
    Working air temp range (-20℃)—45℃
    compressor Type   Panasonic
    Air source heat exchanger Type   Finned heat exchange
    Fan Type   axial flow fan
    Hot water side heat exchange Type   Coil heat exchanger
    Water flow L/H 2000L/h
    Water pressure down Kpa 30
    Pipe size DN 20
    Max flat square meter M2 55
    MODEL Unit MD30D
    Rated heating capacity KW 12
    Rated Cooling capacity   7
    Hot water supply L/h 260
    Average heating input power KW 3
    Rated heating input current A 13/6
    Max outlet water temp 60
    COP   4
    Power V/Hz 220V/380/50
    Noise Db(a) 54
    Dimension W*D*H mm 1120*490*710mm
    Packing size W*D*H mm 1190*520*865mm
    Unit weight KG 108
    Refrigerant   R417A/R407C/R404A
    Working air temp range   (-20℃)—45℃
    compressor Type   Copeland
    Air source heat exchanger Type   Finned heat exchange
    Fan Type   axial flow fan
    Hot water side heat exchange Type   Coil heat exchanger
    Water flow L/H 3000L/h
    Water pressure down Kpa 40
    Pipe size DN 25
    Max flat square meter M2 100
    MODEL Unit MD40D
    Rated heating capacity KW 16
    Rated Cooling capacity   10
    Hot water supply L/h 360
    Average heating input power KW 4
    Rated heating input current A 9
    Max outlet water temp 60
    COP   4.2
    Power V/Hz 380V/50
    Noise Db(a) 55
    Dimension W*D*H mm 1120*490*1270
    Packing size W*D*H mm 1200*520*1425
    Unit weight KG 160
    Refrigerant   R417A/R407C/R404A
    Working air temp range   (-20℃)—45℃
    compressor Type   Copeland
    Air source heat exchanger Type   Finned heat exchange
    Fan Type   axial flow fan
    Hot water side heat exchange Type   Coil heat exchanger
    Water flow L/H 4000L/h
    Water pressure down Kpa 45
    Pipe size DN 25
    Max flat square meter M2 125
    MODEL Unit MD50D
    Rated heating capacity KW 18
    Rated Cooling capacity   12
    Hot water supply L/h 400
    Average heating input power KW 4.4
    Rated heating input current A 9
    Max outlet water temp C 60
    COP   4.2
    Power V/Hz 380V/50
    Noise Db(a) 55
    Dimension W*D*H mm 1120*490*1270
    Packing size W*D*H mm 1200*520*1425
    Unit weight KG 160
    Refrigerant   R417A/R407C/R404A
    Working air temp range   (-20℃)—45℃
    compressor Type   Copeland
    Air source heat exchanger Type   Finned heat exchange
    Fan Type   axial flow fan
    Hot water side heat exchange Type   Coil heat exchanger
    Water flow L/H 5000L/h
    Water pressure down Kpa 45
    Pipe size DN 25
    Max flat square meter M2 150
    MODEL Unit MD60D
    Rated heating capacity KW 21
    Rated Cooling capacity   15
    Hot water supply L/h 520
    Average heating input power KW 5.68
    Rated heating input current A 12
    Max outlet water temp 60
    COP   4.2
    Power V/Hz 380/50
    Noise Db(a) 60
    Dimension W*D*H mm 1120*490*1270
    Packing size W*D*H mm 1200*520*1425
    Unit weight KG 210
    Refrigerant   R417A/R407C/R404A
    Working air temp range   (-20℃)—45℃
    compressor Type   Copeland
    Air source heat exchanger Type   Finned heat exchange
    Fan Type   axial flow fan
    Hot water side heat exchange Type   Coil heat exchanger
    Water flow L/H 6000
    Water pressure down Kpa 48
    Pipe size DN 25
    Max flat square meter M2 175
    MODEL Unit MD100D
    Rated heating capacity KW 36
    Rated Cooling capacity   24
    Hot water supply L/h 800
    Average heating input power KW 9.2
    Rated heating input current A 18
    Max outlet water temp 60
    COP   4.2
    Power V/Hz 380V/50
    Noise Db(a) 60
    Dimension W*D*H mm 1450×760×1060
    Packing size W*D*H mm 1520*800*1230
    Unit weight KG 289
    Refrigerant   R417A/R407C/R404A
    Working air temp range   (-20℃)—45℃
    compressor Type   Copeland
    Air source heat exchanger Type   Finned heat exchange
    Fan Type   axial flow fan
    Hot water side heat exchange Type   Coil heat exchanger
    Water flow L/H 10000L/h
    Water pressure down Kpa 54
    Pipe size DN 32
    Max flat square meter M2 300
    MODEL Unit MD150D
    Rated heating capacity KW 42
    Rated Cooling capacity   29
    Hot water supply L/h 1200
    Average heating input power KW 11
    Rated heating input current A 18
    Max outlet water temp 60
    COP   4.2
    Power V/Hz 380V/50
    Noise Db(a) 60
    Dimension W*D*H mm 1450×760×1060
    Packing size W*D*H mm 1520*800*1230
    Unit weight KG 320
    Refrigerant   R417A/R407C/R404A
    Working air temp range   (-20℃)—45℃
    compressor Type   Copeland
    Air source heat exchanger Type   Finned heat exchange
    Fan Type   axial flow fan
    Hot water side heat exchange Type   Coil heat exchanger
    Water flow L/H 15000L/h
    Water pressure down Kpa 54
    Pipe size DN 32
    Max flat square meter M2 350
    MODEL Unit MD200D
    Rated heating capacity KW 72
    Rated Cooling capacity   48
    Hot water supply L/h 1590
    Average heating input power KW 18.2
    Rated heating input current A 35
    Max outlet water temp 60
    COP   4.5
    Power V/Hz 380V/50
    Noise Db(a) 65
    Dimension W*D*H mm 2040×1100×2000
    Packing size W*D*H mm 2080×1150×2130
    Unit weight KG 650
    Refrigerant   R417A/R407C/R404A
    Working air temp range   (-20℃)—45℃
    compressor Type   Copeland
    Air source heat exchanger Type   Finned heat exchange
    Fan Type   axial flow fan
    Hot water side heat exchange Type   Coil heat exchanger
    Water flow L/H 20000L/h
    Water pressure down Kpa 60
    Pipe size DN 50
    Max flat square meter M2 600
    MODEL Unit MD300D
    Rated heating capacity KW 88
    Rated Cooling capacity   65
    Hot water supply L/h 24000
    Average heating input power KW 25
    Rated heating input current A 45
    Max outlet water temp 60
    COP   4.5
    Power V/Hz 380V/50
    Noise Db(a) 68
    Dimension W*D*H mm 2040×1100×2000
    Packing size W*D*H mm 2080×1150×2130
    Unit weight KG 650
    Refrigerant   R417A/R407C
    Working air temp range   (-20℃)—45℃
    compressor Type   Copeland
    Air source heat exchanger Type   Finned heat exchange
    Fan Type   axial flow fan
    Hot water side heat exchange Type   Coil heat exchanger
    Water flow L/H 30000L/h
    Water pressure down Kpa 60
    Pipe size DN 50
    Max flat square meter M2 730

     

     